These issues are being addressed: 1. Co-requisite to IMS PA APAR PI40457 - RLDS support in DBRC options in System Definitions. 2. If certain log record types (IMS X'4E' - Monitor) are extracted by IMS PI the records may be subsequently corrupted in processing the extract data set. 3. Support IMS Service updates which may modify the contents or construct of IMS, Connect and other log record types. 4. Forward fit of IMS Problem Investigator V230 APAR PI41839 (Random abends {eg S0C4, S0C6} processing IMS V13 log with records containing compressed data). ABEND0C4 ABENDS0C4 ABEND0C6 ABENDS0C6 Another symptom of this found: ABEND0C1 in ALZ991 ( ALZ99D ) at x'4B9A' when processing compressed data. ABENDS0C1 S0C1 5. Filtering on DB2 LUWID may fail under some circumstances. If a Filter for a specific DB2 log code (e.g. DB2 0020 - UR control) contains a condition defining a specific LUWID then no results will be returned, even if there are records that validly satisfy the criteria. The composite key containing the LUWID component parts used for comparison checking was not being constructed in the case of specific record codes, only in the case of CODE=ALL being used.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Problem Investigator V2.4 * **************************************************************** * PROBLEM DESCRIPTION: Co-requisite to IMS PA APAR PI40457 - * * RLDS support in DBRC options in * * System Definitions. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR addresses the following issues: 1. Co-requisite to IMS PA APAR PI40457 - RLDS support in DBRC options in System Definitions. 2. If certain log record types (IMS X'4E' - Monitor) are extracted by IMS PI the records may be subsequently corrupted in processing the extract data set. 3. Support IMS Service updates which may modify the contents or construct of IMS, Connect and other log record types. 4. Random abends (eg S0C4, S0C6) processing IMS V13 log with records containing compressed data. 5. Filtering on DB2 LUWID may fail under some circumstances.
Problem conclusion
The following changes have been made for the above issues: 1. System Definitions may be shared between IMS PA and IMS PI, PI40457 introduces RLDS support into DBRC Options in IMS PA V4.4, this option must also be supported in IMS PI V2.4. 2. IMS X'4E' Monitor records are de-blocked and require pre-processing in IMS PI for an online Monitor session. If these records are subsequently extracted and the extract is processed by IMS PI the pre-processing of these records is no longer required. Extracted records must be identified on input and flagged as not requiring pre-processing which may corrupt the extracted record. 3. Update Knowledge Modules impacted by IMS Service changes. 4. The IMS x'9904' record may be truncated at any point and a continuation record created. If the truncation occurs in a block of compressed data, which is then passed to the Data Compression and Expansion routine to be expanded with the original non-truncated length specified, the expansion fails but during the process unrelated storage may be overlaid at random causing subsequent abends to occur. In processing for the IMS x'9904' record, before calling the Data Compression routine to expand compressed data the supplied length must be validated against the actual data length to ensure truncation has not occurred. 5. If a Filter for a specific DB2 log code (e.g. DB2 0020 - UR control) contains a condition defining a specific LUWID then no results will be returned, even if there are records that validly satisfy the criteria. The composite key containing the LUWID component parts used for comparison checking was not being constructed in the case of specific record codes, only in the case of CODE=ALL being used.
Temporary fix
Comments
APAR Information
APAR number
PI40569
Reported component name
IMS PROBLEM INV
Reported component ID
5655K5000
Reported release
240
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-05-06
Closed date
2015-06-25
Last modified date
2015-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI28851
Modules/Macros
ALZ##PRO ALZ#GINF ALZ#LFDS ALZ#NV21 ALZ#NV22 ALZ#RTYP ALZ#SC00 ALZ#SFRL ALZ#Z003 ALZAT00Y ALZA0A19 ALZA0A49 ALZA0A99 ALZA0109 ALZA0119 ALZA0129 ALZA0139 ALZA0149 ALZA0159 ALZA0169 ALZA0179 ALZA02A9 ALZA02B9 ALZA02C9 ALZA02D9 ALZA0299 ALZA03E9 ALZA0389 ALZA0399 ALZA0419 ALZA0429 ALZA0439 ALZA0449 ALZA05 ALZA0589 ALZA06A9 ALZA0699 ALZA07B9 ALZA0749 ALZA0779 ALZA0789 ALZBATCH ALZBRAPI ALZBRCOP ALZBRFMT ALZBRMIO ALZBRPRE ALZCA01A ALZCDOLI ALZDBRC ALZDBRCA ALZDBRCD ALZDBRCF ALZDBRCJ ALZDBRCM ALZDBRCR ALZDBRCT ALZDBRCX ALZE0803 ALZE0804 ALZIMSPA ALZLCAT ALZLFMER ALZLRFIL ALZPRDRV ALZSDAPI ALZSDDEC ALZSDEV ALZSDGV ALZSDRCV ALZSDRD4 ALZSDSAV ALZ0B01S ALZ01A ALZ01B ALZ01C ALZ01D ALZ01E ALZ07A ALZ07B ALZ07C ALZ07D ALZ07E ALZ0701S ALZ0702S ALZ22A ALZ22B ALZ22C ALZ22D ALZ22E ALZ31A ALZ31B ALZ31C ALZ31D ALZ31E ALZ32A ALZ32B ALZ32C ALZ32D ALZ32E ALZ35A ALZ35B ALZ35C ALZ35D ALZ35E ALZ36A ALZ36B ALZ36C ALZ36D ALZ36E ALZ37A ALZ37B ALZ37C ALZ37D ALZ37E ALZ38A ALZ38B ALZ38C ALZ38D ALZ38E ALZ4003A ALZ4003B ALZ4003C ALZ4003D ALZ4003E ALZ4010A ALZ4010B ALZ4010C ALZ4010D ALZ4010E ALZ4014A ALZ4014B ALZ4014C ALZ4014D ALZ4014E ALZ4040A ALZ4040B ALZ4040C ALZ4040D ALZ4040E ALZ4082A ALZ4082B ALZ4082C ALZ4082D ALZ4082E ALZ45FFA ALZ45FFB ALZ45FFC ALZ45FFD ALZ45FFE ALZ4502A ALZ4502B ALZ4502C ALZ4502D ALZ4502E ALZ4512A ALZ4512B ALZ4512C ALZ4512D ALZ4512E ALZ4513A ALZ4513B ALZ4513C ALZ4513D ALZ4513E ALZ4516B ALZ4516C ALZ4516D ALZ4516E ALZ4519E ALZ55A ALZ55B ALZ55C ALZ55D ALZ55E ALZ5501A ALZ5501B ALZ5501C ALZ5501D ALZ5501E ALZ5921A ALZ5921B ALZ5921C ALZ5921D ALZ5921E ALZ5961D ALZ5961E ALZ64A ALZ64B ALZ64C ALZ64D ALZ64E ALZ67D0A ALZ67D0B ALZ67D0C ALZ67D0D ALZ67D0E ALZ67FDA ALZ67FDB ALZ67FDC ALZ67FDD ALZ67FDE ALZ6701A ALZ6701B ALZ6701C ALZ6701D ALZ6701E ALZ6705A ALZ6705B ALZ6705C ALZ6705D ALZ6705E ALZ6740A ALZ6740B ALZ6740C ALZ6740D ALZ6740E ALZ70A ALZ70B ALZ70C ALZ70D ALZ70E ALZ72A ALZ72B ALZ72C ALZ72D ALZ72E ALZ99A ALZ99B ALZ99C ALZ99D ALZ99E
SC19436700 |
Fix information
Fixed component name
IMS PROBLEM INV
Fixed component ID
5655K5000
Applicable component levels
R240 PSY UI28851
UP15/06/30 P F506
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A4","label":"IMS Problem Investigator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.4.0"}]
Document Information
Modified date:
14 December 2020