  • These issues are being addressed:
    1. Co-requisite to IMS PA APAR PI40457 - RLDS support in DBRC
       options in System Definitions.
    2. If certain log record types (IMS X'4E' - Monitor) are
       extracted by IMS PI the records may be subsequently
       corrupted in processing the extract data set.
    3. Support IMS Service updates which may modify the contents or
       construct of IMS, Connect and other log record types.
    4. Forward fit of IMS Problem Investigator V230 APAR PI41839
       (Random abends {eg S0C4, S0C6} processing IMS V13 log with
       records containing compressed data).  ABEND0C4 ABENDS0C4
                                             ABEND0C6 ABENDS0C6
       Another symptom of this found: ABEND0C1 in ALZ991 ( ALZ99D )
       at x'4B9A' when processing compressed data.   ABENDS0C1 S0C1
    5. Filtering on DB2 LUWID may fail under some circumstances.
       If a Filter for a specific DB2 log code (e.g. DB2 0020 - UR
       control) contains a condition defining a specific LUWID then
       no results will be returned, even if there are records that
       validly satisfy the criteria. The composite key containing
       the LUWID component parts used for comparison checking was
       not being constructed in the case of specific record codes,
       only in the case of CODE=ALL being used.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Problem Investigator V2.4       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Co-requisite to IMS PA APAR PI40457 -   *
    *                      RLDS support in DBRC options in         *
    *                      System Definitions.                     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR addresses the following issues:
    1. Co-requisite to IMS PA APAR PI40457 - RLDS support in DBRC
       options in System Definitions.
    2. If certain log record types (IMS X'4E' - Monitor) are
       extracted by IMS PI the records may be subsequently corrupted
       in processing the extract data set.
    3. Support IMS Service updates which may modify the contents or
       construct of IMS, Connect and other log record types.
    4. Random abends (eg S0C4, S0C6) processing IMS V13 log with
       records containing compressed data.
    5. Filtering on DB2 LUWID may fail under some circumstances.
    

Problem conclusion

  • The following changes have been made for the above issues:
    1. System Definitions may be shared between IMS PA and IMS PI,
       PI40457 introduces RLDS support into DBRC Options in IMS
       PA V4.4, this option must also be supported in IMS PI V2.4.
    2. IMS X'4E' Monitor records are de-blocked and require
       pre-processing in IMS PI for an online Monitor session.
       If these records are subsequently extracted and the extract
       is processed by IMS PI the pre-processing of these records
       is no longer required. Extracted records must be identified
       on input and flagged as not requiring pre-processing which
       may corrupt the extracted record.
    3. Update Knowledge Modules impacted by IMS Service changes.
    4. The IMS x'9904' record may be truncated at any point and a
       continuation record created. If the truncation occurs in a
       block of compressed data, which is then passed to the Data
       Compression and Expansion routine to be expanded with the
       original non-truncated length specified, the expansion
       fails but during the process unrelated storage may be
       overlaid at random causing subsequent abends to occur.
       In processing for the IMS x'9904' record, before calling
       the Data Compression routine to expand compressed data the
       supplied length must be validated against the actual data
       length to ensure truncation has not occurred.
    5. If a Filter for a specific DB2 log code (e.g. DB2 0020 -
       UR control) contains a condition defining a specific LUWID
       then no results will be returned, even if there are records
       that validly satisfy the criteria. The composite key
       containing the LUWID component parts used for comparison
       checking was not being constructed in the case of specific
       record codes, only in the case of CODE=ALL being used.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI40569

  • Reported component name

    IMS PROBLEM INV

  • Reported component ID

    5655K5000

  • Reported release

    240

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-05-06

  • Closed date

    2015-06-25

  • Last modified date

    2015-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI28851

Modules/Macros

  •    ALZ##PRO ALZ#GINF ALZ#LFDS ALZ#NV21 ALZ#NV22
    ALZ#RTYP ALZ#SC00 ALZ#SFRL ALZ#Z003 ALZAT00Y ALZA0A19 ALZA0A49
    ALZA0A99 ALZA0109 ALZA0119 ALZA0129 ALZA0139 ALZA0149 ALZA0159
    ALZA0169 ALZA0179 ALZA02A9 ALZA02B9 ALZA02C9 ALZA02D9 ALZA0299
    ALZA03E9 ALZA0389 ALZA0399 ALZA0419 ALZA0429 ALZA0439 ALZA0449
    ALZA05   ALZA0589 ALZA06A9 ALZA0699 ALZA07B9 ALZA0749 ALZA0779
    ALZA0789 ALZBATCH ALZBRAPI ALZBRCOP ALZBRFMT ALZBRMIO ALZBRPRE
    ALZCA01A ALZCDOLI ALZDBRC  ALZDBRCA ALZDBRCD ALZDBRCF ALZDBRCJ
    ALZDBRCM ALZDBRCR ALZDBRCT ALZDBRCX ALZE0803 ALZE0804 ALZIMSPA
    ALZLCAT  ALZLFMER ALZLRFIL ALZPRDRV ALZSDAPI ALZSDDEC ALZSDEV
    ALZSDGV  ALZSDRCV ALZSDRD4 ALZSDSAV ALZ0B01S ALZ01A   ALZ01B
    ALZ01C   ALZ01D   ALZ01E   ALZ07A   ALZ07B   ALZ07C   ALZ07D
    ALZ07E   ALZ0701S ALZ0702S ALZ22A   ALZ22B   ALZ22C   ALZ22D
    ALZ22E   ALZ31A   ALZ31B   ALZ31C   ALZ31D   ALZ31E   ALZ32A
    ALZ32B   ALZ32C   ALZ32D   ALZ32E   ALZ35A   ALZ35B   ALZ35C
    ALZ35D   ALZ35E   ALZ36A   ALZ36B   ALZ36C   ALZ36D   ALZ36E
    ALZ37A   ALZ37B   ALZ37C   ALZ37D   ALZ37E   ALZ38A   ALZ38B
    ALZ38C   ALZ38D   ALZ38E   ALZ4003A ALZ4003B ALZ4003C ALZ4003D
    ALZ4003E ALZ4010A ALZ4010B ALZ4010C ALZ4010D ALZ4010E ALZ4014A
    ALZ4014B ALZ4014C ALZ4014D ALZ4014E ALZ4040A ALZ4040B ALZ4040C
    ALZ4040D ALZ4040E ALZ4082A ALZ4082B ALZ4082C ALZ4082D ALZ4082E
    ALZ45FFA ALZ45FFB ALZ45FFC ALZ45FFD ALZ45FFE ALZ4502A ALZ4502B
    ALZ4502C ALZ4502D ALZ4502E ALZ4512A ALZ4512B ALZ4512C ALZ4512D
    ALZ4512E ALZ4513A ALZ4513B ALZ4513C ALZ4513D ALZ4513E ALZ4516B
    ALZ4516C ALZ4516D ALZ4516E ALZ4519E ALZ55A   ALZ55B   ALZ55C
    ALZ55D   ALZ55E   ALZ5501A ALZ5501B ALZ5501C ALZ5501D ALZ5501E
    ALZ5921A ALZ5921B ALZ5921C ALZ5921D ALZ5921E ALZ5961D ALZ5961E
    ALZ64A   ALZ64B   ALZ64C   ALZ64D   ALZ64E   ALZ67D0A ALZ67D0B
    ALZ67D0C ALZ67D0D ALZ67D0E ALZ67FDA ALZ67FDB ALZ67FDC ALZ67FDD
    ALZ67FDE ALZ6701A ALZ6701B ALZ6701C ALZ6701D ALZ6701E ALZ6705A
    ALZ6705B ALZ6705C ALZ6705D ALZ6705E ALZ6740A ALZ6740B ALZ6740C
    ALZ6740D ALZ6740E ALZ70A   ALZ70B   ALZ70C   ALZ70D   ALZ70E
    ALZ72A   ALZ72B   ALZ72C   ALZ72D   ALZ72E   ALZ99A   ALZ99B
    ALZ99C   ALZ99D   ALZ99E
    

Publications Referenced
SC19436700    

Fix information

  • Fixed component name

    IMS PROBLEM INV

  • Fixed component ID

    5655K5000

Applicable component levels

  • R240 PSY UI28851

       UP15/06/30 P F506

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A4","label":"IMS Problem Investigator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.4.0"}]

Document Information

Modified date:
14 December 2020