A fix is available
APAR status
Closed as program error.
Error description
Recovery from IGZ0006S via EXEC CICS HANDLE ABEND ends with message: CEE1001E A cross program branching was attempted as a result of a CICS HANDLE command with the LABEL options. This was not supported by the language used by program IGZXCMSG. An ABENDAPC2 is subsequent failure with message CEE3250C The system or user abend APC2 was issued being emitted. Note: ABEND issued from CEEWUCHA's handling of recovery via USRHDLR(CEEWUCHA) option.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL V5 users running under CICS * * who use EXEC CICS HANDLE ABEND LABEL. * * * **************************************************************** * PROBLEM DESCRIPTION: Control after an abend caused by an IGZ * * condition does not get resumed at the * * specified LABEL when using the sample * * user condition handler CEEWUCHA. * * * **************************************************************** * RECOMMENDATION: * **************************************************************** Enterprise COBOL V5 runtime should ignore library DSAs when determining if a cross program branch is being done.
Problem conclusion
The runtime event handler is changed to bypass library DSAs when attempting to transfer control to an abend LABEL.
Temporary fix
Comments
APAR Information
APAR number
PI38705
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
790
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-04-08
Closed date
2015-04-15
Last modified date
2015-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZXLPKA
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.