Closed as program error.
Error description
After web publishing an IBM Rational Software Architect model, links to other model elements within a model element's 'Documentation' tab are broken. The following steps reproduce the problem: 1. Create a UML model and project 2. Add, for example, a class to the model 3. Add, for example, a package to the model and a class to the package 4. Go to the 'Documentation' tab in the class from Step 2 and click 'Add link' in order to create a link to the class created in Step 3 5. Save the changes and web publish the model 6. Open the web published model and click the link from Step 4 Expected Result: You are taken to the class from Step 3 Actual Result: The 'The webpage cannot be displayed' error appears, as the link is broken. There is no workaround.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * - * **************************************************************** * PROBLEM DESCRIPTION: * * "URL Links from documentation contents are usually external * * links and hence they were never processed and left * * untouched. In this was it was an URI pointing to the * * workspace resource and hence it was not navigating to it * * properly from the published content. * * " * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Now, the internal references to workspace resources will be resolved to the correct generated html page (in case, if they are generated properly by resolving the location) and hence the navigating will work seamlessly.
Temporary fix
Comments
APAR Information
APAR number
PI35064
Reported component name
RATL SW ARCHITE
Reported component ID
5725A3000
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-02-16
Closed date
2015-06-05
Last modified date
2015-06-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL SW ARCHITE
Fixed component ID
5725A3000
Applicable component levels
R900 PSY
UP
R910 PSY
UP
R911 PSY
UP