A fix is available
APAR status
Closed as program error.
Error description
There is an exposure when Query Monitor is monitoring many DB2s that can cause an internal overlay that results in an SA78 ABEND. Symptoms include: DB2 QUERY MONITOR TTXTW SUBTASK ABEND AB/S0A78 System abend code: 0A78 PRCS/00000010 Abend reason code: 00000010
Local fix
Split Query Monitor into 2 CQM subsystems monitoring no more than 8 DB2 ssids each.
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Query MOnitor. * **************************************************************** * PROBLEM DESCRIPTION: There is an exposure when Query Monitor * * is monitoring many DB2s that can cause * * an internal overlay that results in an * * SA78 ABEND. Symptoms include: * * DB2 QUERY MONITOR TTXTW SUBTASK ABEND * * AB/S0A78 System abend code: 0A78 * * PRCS/00000010 * * Abend reason code: 00000010 * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PI34116
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-02-03
Closed date
2015-06-04
Last modified date
2016-03-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI28243 UI28244
Modules/Macros
CQM#EXCP
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 March 2016