A fix is available
APAR status
Closed as program error.
Error description
DSNKINSL:5033 due to missing index update log. It is possible Index Manager missed SetWrite.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All DB2 10 AND DB2 11 for z/OS users using * * indexes. * **************************************************************** * PROBLEM DESCRIPTION: ABEND04E RC00C90101 DSNKINSL * * ERQUAL5033 was encountered * * AFTER DB2 RESTART. * **************************************************************** * RECOMMENDATION: * **************************************************************** During LPAR failure testing, an index manager log record was not properly written to DASD prior to the failure, resulting in the following abend after the subsequent DB2 restart: ABEND04E RC00C90101 DSNKINSL erqual5033
Problem conclusion
Index manager code was changed to check if proper index page latch is held and the index page is marked as dirty before a key is inserted into an index leaf page or deleted from an index leaf page. Following diagnostic abends could be issued when index manager code detects missing page latch or page set write error: Abend04E RC00C90101 DSNKINSL ERQUAL506E Abend04E RC00C90101 DSNKINSL ERQUAL506F Abend04E RC00C90101 DSNKDLE ERQUAL506E Abend04E RC00C90101 DSNKDLE ERQUAL506F
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PI32991
Reported component name
DB2 OS/390 & Z/
Reported component ID
5740XYR00
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-01-19
Closed date
2015-03-12
Last modified date
2015-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
010PC2 UI25905 010PC2 010PC2 UI25906 010PC2 010PC2
Modules/Macros
DSNKDLE DSNKINSL
Fix information
Fixed component name
DB2 OS/390 & Z/
Fixed component ID
5740XYR00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
06 May 2020