Fixes are available
Rational Integration Tester 8.7
Rational Test Virtualization Server 8.7
Rational Performance Test Server 8.7
Rational Test Virtualization Server Fix Pack 1 (8.7.0.1) for 8.7
Rational Integration Tester Fix Pack 1 (8.7.0.1) for 8.7
Rational Performance Test Server Fix Pack 2 (8.7.0.2) for 8.7
Rational Integration Tester Fix Pack 2 (8.7.0.2) for 8.7
Rational Test Virtualization Server Fix Pack 2 (8.7.0.2) for 8.7
Rational Test Virtualization Server Fix Pack 3 (8.7.0.3) for 8.7
Rational Integration Tester Fix Pack 3 (8.7.0.3) for 8.7
Rational Performance Test Server Fix Pack 1 (8.7.0.1) for 8.7
Rational Integration Tester Fix Pack 4 (8.7.0.4) for 8.7
Rational Test Virtualization Server Fix Pack 4 (8.7.0.4) for 8.7
Rational Performance Test Server Fix Pack 4 (8.7.0.4) for 8.7
Rational Performance Test Server Fix Pack 3 (8.7.0.3) for 8.7
APAR status
Closed as program error.
Error description
It is not possible to configure the Default check-box in the Results Publishers configuration. WORKAROUND: 1. Configure your test suite Publish Results tab. 2. Click the Set as default button. The Default check-box will now be set in Project Settings > Results Publishers
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration Tester working with test * * suites. * **************************************************************** * PROBLEM DESCRIPTION: * * "Project Settings > Results Publishers" showed a check box * * to indicate which publisher, if any, was the default. This * * display was confusing because the value for the check box * * could not be changed in the project settings. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
A fix for this issue was provided in version 8.7.0 of Rational Integration Tester. The check box has been replaced with a "Yes" or "No" text field that the user cannot change.
Temporary fix
Comments
APAR Information
APAR number
PI31969
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
860
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-12-23
Closed date
2015-05-21
Last modified date
2015-05-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSY
UP
Document Information
Modified date:
14 October 2021