IBM Support

PI30306: ABENDS04E RC00E7000C IN WLM, IN CQMOXGAX + X' 2D5A ', ABENDS0C4 IN CQMMPRA1 + X' 123E ', DB2 ABENDS0D6 MAY OCCUR.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PI27125 is recommended as a resolving APAR for PI17576.  After
    installing PI27125 a symptom of the PI17576 can still occur.
    There is an exposure in the CQM GETPAGE collection processor
    that could S0c4 in a window prior to actual collection.  The CQM
    Getpage collection recovery handler is testing and verifying
    retry states and there is an opening where the CQM recovery
    needs to be, but was not in, AMODE 64.
    The resolving APAR will make sure CQM is in AMODE64.
    .
    The following symptoms may occur after applying PI27125:
     1. ABEND S04E R=00E7000C may occur in WLM
     2. ABEND may occur in CQMOXGAX+2D5a and may cause DB2 to
        generate a dump similar to: DSN ,ABND=0C4-00000010,U=authid
        ,M=N,C=101.LOCN=::locname ,PSW=070C000090802D5A,A=0058
     3. ABND=0C4-00000011 may occur in CQMMPRA1+123E
     4. DB2 ABND=0D6 may occur
    

Local fix

  • Add OBJECTS(N) to the CQMPARMS parameter file to stop this
    symptom from occurring (stop and restart the collector to
    activate the parameter).
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: PI27125 is recommended as a resolving   *
    *                      APAR for PI17576.  After installing     *
    *                      PI27125 a symptom of the PI17576 can    *
    *                      still occur. There is an exposure in    *
    *                      the CQM GETPAGE collection processor    *
    *                      that could S0c4 in a window prior to    *
    *                      actual collection.  The CQM Getpage     *
    *                      collection recovery handler is testing  *
    *                      and verifying retry states and there    *
    *                      is an opening where the CQM recovery    *
    *                      needs to be, but was not in, AMODE 64.  *
    *                      The resolving APAR will make sure CQM   *
    *                      is in AMODE64.                          *
    *                      The following symptoms may occur after  *
    *                      applying PI27125:                       *
    *                       1. ABEND S04E R=00E7000C may occur     *
    *                       in WLM                                 *
    *                       2. ABEND may occur in CQMOXGAX+2D5a    *
    *                       and may cause DB2 to generate a dump   *
    *                       similar to: DSN ,ABND=0C4-00000010,    *
    *                       U=authid,M=N,C=101.LOCN=::locname ,    *
    *                       PSW=070C000090802D5A,A=0058            *
    *                       3. ABND=0C4-00000011 may occur in      *
    *                       CQMMPRA1+123E                          *
    *                       4. DB2 ABND=0D6 may occur              *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI30306

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-11-24

  • Closed date

    2015-01-13

  • Last modified date

    2015-02-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI24360 UI24361

Modules/Macros

  • CQM#BCMX CQM#RESM CQM#REST CQMISMAX CQMISMPX
    CQMISMSX CQMMALOX CQMMCMDX CQMMEACX CQMMEAPX CQMMEARX CQMMEASX
    CQMMEBCX CQMMEBPX CQMMEBRX CQMMEBSX CQMMEMTX CQMMESA1 CQMMESB1
    CQMMESQX CQMMES81 CQMMES91 CQMMEXCX CQMMEXXX CQMME8CX CQMME8PX
    CQMME8RX CQMME8SX CQMME9CX CQMME9PX CQMME9RX CQMME9SX CQMMHSTX
    CQMMHSX9 CQMMINDX CQMMINST CQMMMETX CQMMPRA1 CQMMPRB1 CQMMPR81
    CQMMPR91 CQMMSACX CQMMSAPX CQMMSARX CQMMSASX CQMMSBCX CQMMSBPX
    CQMMSBRX CQMMSBSX CQMMSCLX CQMMSQLX CQMMSSQX CQMMSTRX CQMMS8CX
    CQMMS8PX CQMMS8RX CQMMS8SX CQMMS9CX CQMMS9PX CQMMS9RX CQMMS9SX
    CQMMTRA1 CQMMTRB1 CQMMTR91 CQMOXGAX CQMOXGBX CQMOXG8X CQMOXG9X
    CQMPCR1X CQMPCR2X CQMTTEX1 CQMTTXTX
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R310 PSY UI24360

       UP15/01/28 P F501

  • R320 PSY UI24361

       UP15/01/28 P F501

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: