IBM Support

PI30097: OQWT TUNING DOESN'T WORK FOR DB2 WITH PORT MORE THAN 32768

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Activity Browser cannot tune a workload If the port number of
    DB2 is more than 32768 because it uses the wrong port. For
    example, if the port number is 50250 then the Activity Browser
    uses -15286 ( = 50250 - 65536), causing the connect to DB2 to
    fail with message CQMC2540W.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Activity Browser cannot tune a          *
    *                      workload If the port number of DB2 is   *
    *                      more than 32768 because it uses the     *
    *                      wrong port. For example, if the port    *
    *                      number is 50250 then the Activity       *
    *                      Browser uses -15286 ( = 50250 - 65536), *
    *                      causing the connect to DB2 to fail      *
    *                      with message CQMC2540W.                 *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI30097

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-11-20

  • Closed date

    2015-01-29

  • Last modified date

    2015-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • CQMBLOB
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R320 PSY UI24800

       UP15/02/07 P F502

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.