A fix is available
APAR status
Closed as program error.
Error description
A WebSphere Application Server ( WAS ) region received an ABENDS13E directly after commit phase 1 was started for a UOW. This unit-of-work was left 'stranded'. Normally, it would be expected for the queue-manager to shunt long running units of work such as these, but it will not do so if only ACECMT1 is set (it will only be expected that this state is short-lived). This therefore resulted in the queue-manager abending during shutdown (when it tried to backout the unit of work, but the archive log was not available) and when trying to be restarted. CSQJ113E (ssid RBA 14F19DB94000 NOT IN ANY ACTIVE OR ARCHIVE LOG DATA SET CSQY291E CSQWDSDM SDUMPX FAILED, RC=00000B08,ABN=5C6-00D1032A, LOC=CSQJL002.CSQJR003+00000ACA *CSQV086E (ssid QUEUE MANAGER ABNORMAL TERMINATION REASON=00D96031 - ABEND=S6C6 U0000 REASON=00D96031
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 * * Release 1 Modification 0. * **************************************************************** * PROBLEM DESCRIPTION: If an application bound with an RRS * * stub abends or terminates during a * * commit a unit of work may be 'stranded' * * in a state similar to being indoubt, * * but will not be backed out and logs * * will not be shunted as expected for * * long running UOW. * **************************************************************** * RECOMMENDATION: * **************************************************************** A timing window exists for applications bound using a RRS batch adapter, when an abend occurs during commit processing. If an abend occurs in the application after phase 1 commit processing has been started, but not completed for a persistent message, the associated unit of work may become stranded. This results in the UOW being left around for the rest of the active life of the queue manager but does not show the UOW as long running, message CSQJ160I is not output. The log records for the UOW are not shunted in this case, which can result in the queue manager abending during shutdown, and being unable to be restarted, if the archive logs for the UOW are no longer available, as the UOW cannot be backed out.
Problem conclusion
The processing during an abend in this scenario has been updated to treat the unit of work, where only phase 1 of commit processing has been started, as inflight. This results in the unit of work being backed out in this scenario. 100Y CSQARIB CSQ3RRSM CSQ3RRSX
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PI29480
Reported component name
WMQ Z/OS V7
Reported component ID
5655R3600
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-11-13
Closed date
2015-01-16
Last modified date
2015-03-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PI30414 UI24447
Modules/Macros
CSQARIB CSQ3RRSM CSQ3RRSX
Fix information
Fixed component name
WMQ Z/OS V7
Fixed component ID
5655R3600
Applicable component levels
R100 PSY UI24447
UP15/02/04 P F502 ¢