Fixes are available
APAR status
Closed as program error.
Error description
When the proxy makes a request from the RUI which contains a cookie header and the proxy receives a 302 redirect from the server which contains a new Set-Cookie header, the proxy follows the 302 by making a new request to the server. However, this new request only contains the cookies from the Set-Cookie header of the 302 response. The second request from the proxy should contain all cookies, with the new values returned by the server Set-Cookie overriding any cookie values originally sent by the RUI.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * If the server side redirect the request and doesn't response * * the cookies, the following request will fail * **************************************************************** * PROBLEM DESCRIPTION: * * Cookies will be overwrited when redirect happens in rui * * proxy * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
RUI proxy will not overwrite the cookies, all the non-duplicated cookies will be sent to server side
Temporary fix
Comments
APAR Information
APAR number
PI28802
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
901
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-10-31
Closed date
2015-03-23
Last modified date
2015-03-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R801 PSY
UP
R851 PSY
UP
R901 PSY
UP
R911 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]