IBM Support

PI27125: POTENTIAL ABENDS0C4 RC3B ABENDS04E RC00E20991 ON FRR RETRY RECOVERY IF A GETPAGE REQUEST ABENDS 4/10/20 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Potential ABND=0C4-0000003B, ABND=04E-00E20991 on FRR Retry
    Recovery if a GETPAGE request Abends.
    

Local fix

  • Add OBJECTS(N) to the CQMPARMS parameter file (stop and restart
    the collector to activate the parameter).
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Potential ABND=0C4-0000003B,            *
    *                      ABND=04E-00E20991 on FRR Retry          *
    *                      Recovery if a GETPAGE request Abends.   *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

  • ×**** PE14/12/03 PTF IN ERROR. SEE APAR PI30306  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PI27125

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-10-06

  • Closed date

    2014-11-03

  • Last modified date

    2017-08-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI22725 UI22726

Modules/Macros

  • CQM#BCMX CQMMALOX CQMMCMDX CQMMEACX CQMMEAPX
    CQMMEARX CQMMEASX CQMMEBCX CQMMEBPX CQMMEBRX CQMMEBSX CQMMEMTX
    CQMMESA1 CQMMESB1 CQMMESQX CQMMES81 CQMMES91 CQMMEXCX CQMMEXXX
    CQMME8CX CQMME8PX CQMME8RX CQMME8SX CQMME9CX CQMME9PX CQMME9RX
    CQMME9SX CQMMINDX CQMMINST CQMMMETX CQMMPRA1 CQMMPRB1 CQMMPR81
    CQMMPR91 CQMMSACX CQMMSAPX CQMMSARX CQMMSASX CQMMSBCX CQMMSBPX
    CQMMSBRX CQMMSBSX CQMMSQLX CQMMSSQX CQMMSTRX CQMMS8CX CQMMS8PX
    CQMMS8RX CQMMS8SX CQMMS9CX CQMMS9PX CQMMS9RX CQMMS9SX CQMMTRA1
    CQMMTRB1 CQMMTR91 CQMOXGAX CQMOXGBX CQMOXG8X CQMOXG9X CQMTTXTX
    H238310J H238320J
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R310 PSY UI22725

       UP14/11/08 P F411 «

  • R320 PSY UI22726

       UP14/11/08 P F411 «

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: