Fixes are available
APAR status
Closed as program error.
Error description
Uploading an application to the Worklight Application Center through Multi-Protocol Gateway in DataPower may fail On the client side, the following error may be displayed: An error occurred during the upload of the updated application file. On the server side, the following error may be logged: Exception during resource upload. String index out of range: -1 The problem is triggered by MPG adding double quotation marks to the MIME multipart message's boundary in the Content-type header. For example, this header multipart/form-data; boundary=---------------------------2925426766838 becomes multipart/form-data; boundary="---------------------------2925426766838" Additional Keywords: Worklight Versions Affected: 5.x, 6.x Initial Impact: High
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Application Center administration users that upload * * applications * **************************************************************** * PROBLEM DESCRIPTION: * * Uploading an application to the Worklight Application Center * * through Multi-Protocol Gateway in DataPower may fail due to * * to the non support by Apache Wink of mutipart HTTP requests * * containing a boundary value enclosed between double quotes * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
The Apache Wink issue was avoided by removing in a servlet filter the double quotes around the boundary attribute of the HTTP header
Temporary fix
Comments
APAR Information
APAR number
PI23927
Reported component name
WORKLIGHT CONSU
Reported component ID
5725I4301
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-08-17
Closed date
2014-09-10
Last modified date
2014-09-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WORKLIGHT CONSU
Fixed component ID
5725I4301
Applicable component levels
R610 PSY
UP
R620 PSY
UP