Fixes are available
APAR status
Closed as program error.
Error description
Rational Developer for System z 8.5 - RDz - CARMA Endevor RAM customization for disabling "Bypass Generate Processor" not working. CARMA Endevor RAM customization is required to not allow users to "Bypass Generate Processor" (disable this option in CARMA User Interface/UI). The following changes are made to the Endevor RAM CRADEF (P00025 and P01025 constant from N to Y) and CRASTRS (set default value of N) files to accomplish this. CRADEF ------------------------ P00025 STRING 1 Y P01025 STRING 1 Y CRASTRS ------------------------ EN_US 00037P01025 BypassGenProces N Bypass generate processor Description EN_US 00037P01025 BypassGenProces N Bypass generate processor Description After RAM customization is done, an error is received on client when CARMA Element is opened in Browse/Read-only mode. The browse open fails with the following error: An internal error occurred during: "Open A". Parameter 'BypassGenProces'(ParameterId=025) processing error: Attempting to reset the constant value to ''.
Local fix
N/A
Problem summary
Setting certain parameters as constant, such as Bypass Generate Processor, would cause errors when performing an Edit or Browse from Endevor.
Problem conclusion
Endevor client code now properly supports setting parameters as constant for all actions, including Edit and Browse. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V8.5.1.6 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI22443
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
851
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-07-21
Closed date
2015-02-04
Last modified date
2015-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R851 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"851","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]