APAR status
Closed as program error.
Error description
When working with very large data centric representational consistent based diagrams in IBM Rational System Architect (SA), it takes a very long time to open such a diagram. These diagrams could have over 50 symbols and hundreds of relationship lines which require redrawing each time a change is made. When running one or more analytics against the diagram, the consistency check report runs again prior to running the analytic which makes the diagrams seem un-useable resulting in SA to appear un-responsive. NOTE This issue is a corner case with particular custom defined diagram types and custom macro code. WORKAROUNDs You can disable the consistency check report in the session options as follows. - open SA and from Tools menu select Session Options. - select RepConRefreshOnDgmOpen and set it to N That will skip the representational consistency step and the open will be much faster. The side effect of this is that if any definitions changes affecting the diagram took place before this diagram open, they will not be reflected on the diagram. The refresh can always be invoked later, once the diagram is opened by clicking the refresh button. We are looking into improving this process. You can improve the analytic macro performance as follows. Open the diagram on which you want to run the analytic - select one line and right click on it to invoke the context menu - from the context menu select 'Select all Application Interface...' - right click again and from the menu select 'Hide Selected Application Interface...' and confirm - once the lines are hidden, run the analytic Not only that the process completes, but it is relatively fast and one gets to see the symbols changing color, which they wouldn't otherwise see because of the lines. You can also hide the lines and save the diagram and after that all subsequent opens will be fast as well. Your analytic macro may also need to be tweaked. You can choose less items to report on using less colors on the diagram. The best material we have on learning how to write (or edit) a VBA macro for System Architect is the 11-part and 7-part tip series -- under VBA tutorials on this page: http://www.ibm.com/developerworks/rational/products/systemarchit ect/enterprisearchitecturetips.html Additionally, the Green IT plug-in has a VBA macro that runs analytics to display icons next to servers, processes, etc based on their power consumption, carbon footprint, and so forth. The plug-in is here: https://www.ibm.com/developerworks/community/files/app#/file/fec 9d9ef-77bc-4913-9143-6d2f90f6dfd3 In the VBA maco, the basMain module has the subroutines. Additionally instead of report based analytic you can use macro based analytics. Examples of these are included in the System Architect installation. IF you need help writing or improving macros then please contact IBM Global Business Services.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** - the representational consistency processing is slow - unnecessary representational consistency processing during heat map manager runs - unnecessary representational consistency processing during line drawing
Problem conclusion
Client didn't have the correct property set configuration; node symbols were left in DEFINED BY state, so the symbols didn't have the attributes needed to look up the definition so wasteful database queries were being made. A macro has been prepared to correct situation - Macro.mac: User-friendly version. Runs when loaded. Needs diagram open. Can run manually. Presents Started, Finished messages. Saves diagram. The attached corrected usrprops contains the file that should be uploaded to the encyclopedia once the user has used the macro to update each diagram they are interested in keeping. If the usrprops is updated before the macro is run against it then all the definition nodes will be removed when the diagram is opened. There were 2 definitions with non-unique GUIDs as reported but not corrected by Verify?Repair. The attached xml will correct them but the xml should be checked to ensure no data will be lost as changes might have been made since the encyclopedia was supplied to us. Various efficiency improvements have been made, mostly affecting the refresh action for the diagram but should also improve the time to open it. Improvements were also made to the Heat Map Manager. Note the circumventions listed.
Temporary fix
Comments
APAR Information
APAR number
PI22205
Reported component name
TLOGIC SYS ARCH
Reported component ID
5724V68SA
Reported release
B40
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-07-17
Closed date
2014-09-18
Last modified date
2014-09-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC SYS ARCH
Fixed component ID
5724V68SA
Applicable component levels
RB40 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS6RBX","label":"Rational System Architect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.4","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: