A fix is available
APAR status
Closed as new function.
Error description
This APAR enables DBD/PSB/ACB Reversal to provide IMS release and decoded date in the decoded DBD/PSB sources. This enhancement is being implemented as a result of following RFE requirement: - RFE 32442
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 2 (FMID=H27P220) users * * who use the DBD/PSB/ACB Reversal utility. * **************************************************************** * PROBLEM DESCRIPTION: This APAR enhances the DBD/PSB/ACB * * Reversal utility to print the following * * information together with the converted * * IMS DBDGEN or IMS PSBGEN utility * * control statements: * * - The date and time when the DBD, PSB, * * or ACB control block was converted * * to IMS DBDGEN or IMS PSBGEN utility * * control statements. * * - The version of IMS that was used to * * create the control block. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR enhances the DBD/PSB/ACB Reversal utility to print the following information together with the converted IMS DBDGEN or IMS PSBGEN utility control statements: - The date and time when the DBD, PSB, or ACB control block was converted to IMS DBDGEN or IMS PSBGEN utility control statements. - The version of IMS that was used to create the control block. The information is printed in the prologue part at the top of the generated result. The following is an example of the prologue part: TITLE 'ASSEMBLE OF DBDNAME=DSCLSDVN ' * DSNAME=IMSVS.DBDLIB * VOL=IMSVS * DBDGEN DATE 11/22/2013 TIME 19.49 * DECODE DATE 08/01/2014 TIME 10.18.54 * IMS VERSION 13.1 If OPTION ACB_GSAM=YES is specified and IMS PSBGEN utility control statements for GSAM PCBs are converted from a PSB when processing a ACB, the version of IMS that was used to create the PSB is printed in the comment part of the GSAM PCB.
Problem conclusion
Temporary fix
Comments
The following modules and macros have been modified. FABLAPI0 FABNACB0 FABNCOM2 FABNDCTL FABNDST0 FABNICB FABNPCNA FABNPCNB FABNPCNC FABNPCND FABNPCN9 FABNPCTL FABNPDBD FABNPPSB FABNWORK ======================== = DOCUMENTATION CHANGE = ======================== The documentation "IBM IMS Library Integrity Utilities for z/OS V2R2, User's Guide (SC19-3979-00)" is changed. For all the documentation changes, see documentation updates on IMS Tools library site. http://www-01.ibm.com/software/data/db2imstools/ imstools-library.html
APAR Information
APAR number
PI21708
Reported component name
IMS LIBR INTEG
Reported component ID
5655I4200
Reported release
220
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2014-07-09
Closed date
2014-08-08
Last modified date
2014-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI20351
Modules/Macros
FABLAPI0 FABNACB0 FABNDCTL FABNPCNA FABNPCNB FABNPCNC FABNPCND FABNPCN9 FABNPCTL FABNPDBD FABNPPSB
SC19397900 |
Fix information
Fixed component name
IMS LIBR INTEG
Fixed component ID
5655I4200
Applicable component levels
R220 PSY UI20351
UP14/08/12 P F408
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]
Document Information
Modified date:
03 October 2020