Fixes are available
Rational Developer for System z 9.1.1
Rational Developer for System z Interim Fix 1 for 9.1.1
Rational Developer for System z Interim Fix 2 for 9.1.1
Rational Developer for System z Fix Pack 1 (9.1.1.1) for 9.1.1.
Rational Developer for System z Interim Fix 1 for 9.1.1.1
Rational Developer for System z Interim Fix 2 for 9.1.1.1
Rational Developer for System z Fix Pack 1 (9.1.1.2) for 9.1.1.
Rational Developer for System z Interim Fix 1 for 9.1.1.2
Rational Developer for System z Interim Fix 2 for 9.1.1.2
Rational Developer for System z Fix Pack 1 (9.1.1.3) for 9.1.1.
Rational Developer for System z Interim Fix 1 for 9.1.1.3
Rational Developer for System z Fix Pack 1 (9.1.1.4) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.5) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.6) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.7) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.8) for 9.1.1
Rational Developer for System z Fix Pack 9 (9.1.1.9) for 9.1.1
APAR status
Closed as program error.
Error description
Rational Developer for System z (RDz): PL/I Outline view is incorrect within PUT statement which contains some repetition using a DO Clause. The DO clause is wrongly assumed as a new block and the following instructions are wrongly included in this block. Example: PUT SKIP EDIT((A(I) DO I = 1 TO 3)) (A);
Local fix
Problem summary
The PL/I outline view treated DO clauses in stream statements (PUT and GET) like DO statements, leading to miscalculations of the blocks in a PL/I program.
Problem conclusion
Fixed PL/I outline view model handler to recognize DO in stream statements as different from DO statements. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V9.1.1.0 Refresh Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI20952
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
851
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-06-27
Closed date
2014-12-11
Last modified date
2014-12-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R911 PSY
UP
Document Information
Modified date:
17 October 2021