Error description
Abend U0385-1D as a result of a Timing issue with DRF processing OLR record type 2931 with multiple OLRs and multiple READERS.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users using DRF to recover into an active * * OLR with PITR involving multiple OLRS and * * multiple partitions. * **************************************************************** * PROBLEM DESCRIPTION: A timing issue related to the start of * * the 2931 record and the 2930 record was * * fixed. In certain cases the 2931 record * * was not included in the recovery * * resulting in a U0385-1D abend. A full * * second is now allowed between the start * * of the 2931 record and the 2930 record. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** This Apar fixes a timing issue which in certain cases dropped the 2931 record due to a timestamp check, resulting in a U0385-1D abend.
Problem conclusion
The timestamp on a 2931 record preceeds the timestamp on the 2930 record. In certain cases the PITR time excluded the 2931 record which resulted in a U385-1D abend. This addresses an issue when recovering into an active OLR after multiple OLRs have completed.
Temporary fix
Comments
APAR Information
APAR number
PI18815
Reported component name
IMS RCVR SOLUTN
Reported component ID
5655V8600
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-27
Closed date
2014-08-19
Last modified date
2014-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI20693
Modules/Macros
FRXRLRA0 FRXVSTA0
Fix information
Fixed component name
IMS RCVR SOLUTN
Fixed component ID
5655V8600
Applicable component levels
R110 PSN UI20693
UP14/08/22 P F408
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: