Error description

  • The following abend may occur in CUA panel KD2VTCAN "Cancel
    Thread" when autorefresh is on
    
    2014.129 01:18:50.72 KLVER011 ABNORMAL TERMINATION AVERTED:
    CODE(000064) A-PSW(078C2000A3D7D21E) P-PSW(078C2000A3D7D21E)
    R15(000000
     KLVDM002 STRING VARIABLE TOO LONG  S000 U0100  THREAD 2439E020
    TASK 00AC4CD8
    0ABEND PSW 078C2000A3D7D21E (KLVDMVTR+936)  ILC 02  INTC 000D
        R0 00001EE7                                              R8
    24645620 (FSA+6AFAB8)
        R1 00008000                                              R9
    24590083 (FSA+5FA51B)
        R2 2462F4D0 (FSA+699968)                                R10
    23D74176 (KLVDMCLX+22E)
        R3 00000000 (TRC)                                       R11
    23D7C9E8 (KLVDMVTR+100)
        R4 00001EE7                                             R12
    0000B000 (GSA)
        R5 24642A18 (FSA+6ACEB0)                                R13
    24645300 (FSA+6AF798)
        R6 A47B5E80 (FSA+820318)                                R14
    23FB7BE8 (FSA+22080)
        R7 00007F8F                                             R15
    00000000 (TRC)
    

Local fix

  • Turn off autorefresh
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - CUA Interface                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND U0100 IN CUA TASK KLVDMVTR+936,   *
    *                      KLVDM002 STRING VARIABLE TOO LONG.      *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    ABEND U0100 IN CUA TASK KLVDMVTR+936, KLVDM002 STRING VARIABLE
    TOO LONG.
    Incorrect processing of variable in CUA panel KD2VTCAN caused
    the exhaustion of maximum variable length of 32767 (X'7FFF').
    
    PROBLEM CONCLUSION:
    Correct processing of the variable in CUA panel
    KD2VTCAN (Cancel Thread).
    
    KEYWORDS:
    ABEND U0100 IN CUA / KLVDM002 STRING VARIABLE TOO LONG
    

Problem conclusion

  • Correct processing of the variable in CUA panel
    KD2VTCAN (Cancel Thread).
    
    KEYWORDS:
    ABEND U0100 IN CUA / KLVDM002 STRING VARIABLE TOO LONG
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI18018

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-05-15

  • Closed date

    2014-06-30

  • Last modified date

    2014-08-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI19233 UI19234 UI19235

Modules/Macros

  • KD2VTCAN
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UI19233

       UP14/07/02 P F407

  • R511 PSY UI19234

       UP14/07/02 P F407

  • R520 PSY UI19235

       UP14/07/02 P F407

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]