A fix is available
APAR status
Closed as program error.
Error description
With IMS V12 the " CF Write I/O Wait " values are missing from the Fast Path DEDB VSO Summary report.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.3 * **************************************************************** * PROBLEM DESCRIPTION: Monitor reports do not include data * * from SLOG73 events * **************************************************************** * RECOMMENDATION: * **************************************************************** Monitor SLOG73 events are incorrectly handled by the IMS PA de-blocking process as they do not conform to expected standard.
Problem conclusion
Update handling of Monitor SLOG73 events by the de-blocker to provide correctly formatted records for the IMS PA report processors.
Temporary fix
Comments
APAR Information
APAR number
PI15279
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
430
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-04-04
Closed date
2014-04-24
Last modified date
2014-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IPIACLND IPIAFPVS IPIAMSCN IPIATRAC IPISAPAR
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R430 PSY UI17339
UP14/04/30 P F404
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 May 2014