A fix is available
APAR status
Closed as program error.
Error description
This APAR addresses a small window in CQMMESx1 (SQL COLLECTION) where the addressing mode is not reset to 64bit mode, should an S-TAP Filter request ABEND for any reason.
Local fix
Shut down CQM any time S-TAP is being stopped. This will stop all collection activity to avoid the collection process hitting a 2 instruction window.
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Query Monitor. * **************************************************************** * PROBLEM DESCRIPTION: This APAR addresses a small window in * * CQMMESx1 (SQL COLLECTION) where the * * addressing mode is not reset to 64bit * * mode, should an S-TAP Filter request * * ABEND for any reason. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PI14843
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-03-31
Closed date
2014-04-23
Last modified date
2014-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI17296 UI17297
Modules/Macros
CQMMESA1 CQMMESB1 CQMMES81 CQMMES91 CQMMMFRR
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.