Error description
Using ISRSUPC in batch mode to search for a term. Concatenation of two PO datasets in NEWDD DD-Statement as libraries to be searched. Both datasets have same BLKSIZE (27998) and RECFM(VB). But different LRECL (one has 450, the other 256). Both datasets are not large. 48 and 19 tracks are used. When dataset with LRECL 450 is first in concatenation, job ends immedeatly with using CPU-Time near to nothing. And correct result. When the dataset with LRECL 256 is first in concatenation, then job needs a lot of CPU (> 1000 CPU-sec.). We tried in this bad combination to add a DCB=(LRECL=450)-parm to the first LRECL 256 dataset. Then it works as fast as if the LRECL 450 dataset would be in front of concatenation.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All z/OS users using ASMFSUPC to search * * PDSs. * **************************************************************** * PROBLEM DESCRIPTION: ASMFSUPC may loop when searching a * * concatenation containing a variable * * blocked partitioned data set. * **************************************************************** * RECOMMENDATION: * **************************************************************** When ASMFSUPC allocates a data set concatenation to be searched, it opens it using the logical record length of the first data set in the concatenation. If a subsequent data set is a variable blocked partitioned dataset containing records which are longer than the logical record length of the first data set in the concatenation, ASMFSUPC detects this as an error, but this is not adequately handled, resulting in a loop.
Problem conclusion
ASMFSUPC has been modified to allocate the search data set concatenation using the largest data set logical record length of the concatenation.
Temporary fix
Comments
APAR Information
APAR number
PI13704
Reported component name
HLASM TOOLKIT
Reported component ID
569623401
Reported release
16A
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-03-14
Closed date
2014-08-01
Last modified date
2015-10-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI20179 UI20180 UI20181
Modules/Macros
ASMFBLST ASMFBMEM ASMFCLST ASMFDBUG ASMFEMSG ASMFLDEL ASMFLLST ASMFLREV ASMFLSUM ASMFLTOT ASMFMCLS ASMFMTOP ASMFPDEL ASMFPPRM ASMFPRBT ASMFPSRH ASMFRDIO ASMFRDLN ASMFRDWD ASMFSAM ASMFSS55 ASMFSS80 ASMFSUPC ASMFTOPN ASMFUCTL ASMFUPD ASMFUSUM ASMFWCTL ASMFWLST
Fix information
Fixed component name
HLASM TOOLKIT
Fixed component ID
569623401
Applicable component levels
R16A PSY UI20179
UP14/08/05 P F408
R36A PSY UI20180
UP14/08/05 P 1408
R6IM PSY UI20181
UP14/08/05 P E610
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"16A","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSENW6","label":"High Level Assembler and Toolkit Feature"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"16A","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
08 October 2015