APAR status
Closed as duplicate of another APAR.
Error description
An application running builds a group message (using GROUPID ) with an MQRFH2 header. The message is sent to a remote queue manager. When the message is received on the remote queue manager the message group is lost, because the sequence of the MQ headers are in the wrong order when built on the transmission queue of the sending queue manager. The remote queue manager receives the sequence : XQH + RFH2 + MQMDE + message body instead of XQH + MQMDE + RFH2 + message body .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
APAR PM44458 fixed this problem in MQ for z/OS V701 and APAR PM73121 fixed this problem in MQ for z/OS V710. COMMENTS.3
APAR Information
APAR number
PI10011
Reported component name
WMQ Z/OS V7
Reported component ID
5655R3600
Reported release
010
Status
CLOSED DUB
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-01-22
Closed date
2014-04-08
Last modified date
2014-04-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
08 April 2014