IBM Support

PI08152: CORRECT THE BEHAVIOR OF IMS V13 ACBGEN UTILITY WITH BLDPSB=NO FOR FP DBD AND SHARED SECONDARY INDEX

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • After IMS V13 APAR PM85882 is applied, the IMS ACBGEN utility is
    corrected the behavior of the parameter BLDPSB=NO for:
      1. FP DBD and shared secondary index
      2. PSB should be rebuilt when BLDPSB=NO is specified and the
    DBD's physical structure is changed.
    
    This APAR enables the Advanced ACBGEN utility with the IMS V13
    environment in which IMS APAR PM85882 is applied to process
    ACBGEN with BLDPSB=NO same as IMS ACBGEN utility with PM85882
    does.
    
    Without this APAR, the Advanced ACBGEN utility with the IMS V13
    environment will rebuild all the PSBs that referenced the FP
    DBD and shared secondary index whether DBD had a physical
    database structure changes or not.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Library Integrity Utilities for z/OS,    *
    *                 Version 2 Release 1 (FMID=H27P210) users     *
    *                 who use the Advanced ACBGEN utility under    *
    *                 IMS V13.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: By this APAR, the Advanced ACBGEN       *
    *                      utility is corrected not to rebuild     *
    *                      PSBs which references the DBD           *
    *                      (including Full Function database, Fast *
    *                      Path DEDB, Fast Path secondary index,   *
    *                      Full Function primary index, secondary  *
    *                      index and shared secondary index        *
    *                      databases) that does not have a         *
    *                      physical database structure changes     *
    *                      under IMS V13, when parameter BLDPSB=NO *
    *                      is specified on BUILD DBD= control      *
    *                      statement in Advanced ACBGEN utility    *
    *                      jobs. To enable this, Advanced ACBGEN   *
    *                      need the IMS environment with the IMS   *
    *                      APAR PM85882.                           *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    When parameter BLDPSB=NO was specified on BUILD DBD= control
    statement in Advanced ACBGEN utility without this APAR, all the
    PSBs that referenced the FP DB or shared secondary index DB were
    rebuilt whether DBD had a physical database structure changes or
    not.
    
    By this APAR, Advanced ACBGEN utility is corrected not to
    rebuild PSBs which references the DBD (including Full Function
    database, Fast Path DEDB, Fast Path secondary index, Full
    Function primary index, secondary index and shared secondary
    index databases) that does not have a physical database
    structure changes under IMS V13. Advanced ACBGEN utility will
    output same results as IMS ACBGEN does.
    
    To enable this, Advanced ACBGEN needs the IMS environment with
    the IMS APAR PM85882.
    
    If Advanced ACBGEN utility with this APAR runs in the IMS
    environment that does not have APAR PM85882 applied, the results
    has changed. PSBs will not be always rebuild when BLDPSB=NO is
    specified on the BUILD DBD=dbdname control statement and whether
    DBD had a physical database structure changes or not. This
    result is not expected results for BLDPSB=NO parameter. So apply
    IMS APAR PM85882 when this APAR will be applied.
    
    Advanced ACBGEN utility under IMS V10, V11 and V12 is not
    changed by this APAR.
    

Problem conclusion

Temporary fix

Comments

  • This APAR modifies the following modules to fix the problem.
     - FABQDRIV
     - FABQRLVD
     - FABQTASK
    

APAR Information

  • APAR number

    PI08152

  • Reported component name

    IMS LIBR INTEG

  • Reported component ID

    5655I4200

  • Reported release

    210

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-12-16

  • Closed date

    2014-04-24

  • Last modified date

    2014-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI17322

Modules/Macros

  • FABQDRIV FABQRLVD FABQTASK
    

Fix information

  • Fixed component name

    IMS LIBR INTEG

  • Fixed component ID

    5655I4200

Applicable component levels

  • R210 PSY UI17322

       UP14/04/26 P F404

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 May 2014