Fixes are available
APAR status
Closed as program error.
Error description
Headline/Abstract (128 Character limit - 2 lines of 64 chars) : *************************************************************** Rational Developer for System z (RDz) 8.5.1.2: When creating a view in the CARMA repositories view, the new name is malformed. APAR Error Description (unlimited lines of 64 chars): *************************************************************** Rational Developer for System z - RDz - v8.5.1.2: In CARMA repositories view, when creating a new view, the view name is wrongly composed with the concatenation of both fields 'Element' and 'Processor group'. It is then impossible to modify using the 'Change view...' action (it will pop up a wizard where the 'Processor Group' is empty, while the 'Element' field is filled in. Recreation steps: - open the New Endevor view wizard, - fill in the following fields: Environment with 'A' System with 'B' Subsystem with 'C' Type with 'D' Element with 'E' Stage with 'F' and Processor group with 'G' The view name will be defined as: ENV:A,SYS:B,STGID:F,SUBSYS:B,TYPE:D,ELEM:EPGROUP:G instead of ENV:A,SYS:B,STGID:F,SUBSYS:B,TYPE:D,ELEM:E,PGROUP:G (an additional comma after 'ELEM:E') - right click and select 'Change view', the processor group is empty *************************************************************** Local fix: A workaround is to add a comma at the end of the field 'Element' during the creation process. For instance, if you want to define the Element filter with 'PROG*', fill in that field with 'PROG*,'.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: CARMA Endevor users who create filters utilizing the processor group input field. **************************************************************** PROBLEM DESCRIPTION: As the filter was created, a comma was not added prior to adding the value for the processor group. The comma serves as the field separator for the filter. ****************************************************************
Problem conclusion
*************************************************************** Problem Resolution: Updated code to add the comma separator as needed. No new messages or publication updates were introduced. **************************************************************** Additional Keywords: CARMA Endevor Filter processor group comma The problem listed in this APAR has been resolved with IBM Rational Developer for System z V8.5.1.5 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI05581
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-11-06
Closed date
2014-06-27
Last modified date
2014-06-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R851 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
17 October 2021