A fix is available
APAR status
Closed as program error.
Error description
The starting byte offset and byte-length of reference modified PIC U data items that are subordinates in a group were not always being calculated correctly when the data item contains multi-byte UTF-8 encoded Unicode characters.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling and * * running programs that contain reference * * modified PIC U data items that are * * subordinate items in a group. * **************************************************************** * PROBLEM DESCRIPTION: Incorrect result * **************************************************************** * RECOMMENDATION: Apply the IBM-provided PTF * **************************************************************** The starting byte offset and byte-length of reference modified PIC U data items that are subordinates in a group were not always being calculated correctly when the data item contains multi-byte UTF-8 encoded Unicode characters.
Problem conclusion
The compiler was updated to ensure that the starting byte offset and byte-length of reference modified PIC U data items that are subordinates in a group are calculated correctly.
Temporary fix
Comments
APAR Information
APAR number
PH63270
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-09-17
Closed date
2024-09-17
Last modified date
2024-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI98464
UP24/09/28 P F409
R631 PSY UI98465
UP24/09/28 P F409
R632 PSY UI98466
UP24/09/28 P F409
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: