A fix is available
APAR status
Closed as program error.
Error description
In the Local Variables section of the CEEDUMP, an incorrect message may appear. "... was not compiled with the SYM suboption of the TEST option ..."
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 5 and later * * releases running programs compiled with * * NOTEST option and NODWARF suboption that * * generate CEEDUMP information. * **************************************************************** * PROBLEM DESCRIPTION: An incorrect message is being printed * * in a CEEDUMP generated from a COBOL * * program compiled with NOTEST option * * and NODWARF suboption. * **************************************************************** * RECOMMENDATION: Install the provided PTF. * **************************************************************** The actual message being printed in the CEEDUMP (incorrect): "<PROG NAME> was not compiled with the SYM suboption of the TEST option. A formatted variable dump cannot be produced." COB0501T/K COB0502T/K COB0601T/K COB0602T/K COB0603T/K COB0604T/K
Problem conclusion
The problem in the COBOL Runtime has been corrected. The problem was resolved by introducing a new message in COBOL runtime routine for generating a CEEDUMP. New correct message printed in the CEEDUMP (correct): "<PROG NAME> was compiled with NOTEST(NODWARF) or equivalent. A formatted variable dump cannot be produced." For example, in CEEDUMP ... Local Variables: X1 was compiled with NOTEST(NODWARF) or equivalent. A formatted variable dump cannot be produced. DSA for X1: ... WSA for X1: ... RENT STATIC (Initial HEAP) for X1: ... PROGRAM STATIC (WSA24, Data cell, ... ...
Temporary fix
Comments
APAR Information
APAR number
PH62039
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7E0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-06-25
Closed date
2024-07-22
Last modified date
2024-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI97715 UI97716 UI97717 UI97718 UI97719 UI97720
Modules/Macros
IGZBALCT IGZCEV4 IGZCJNI2 IGZCMGEN IGZCMGJA IGZCMGUE IGZEDCCT IGZIBMCT IGZIGZCT IGZLLIBV IGZXAPI IGZXCA31 IGZXCDA IGZXD24 IGZXDMR IGZXJNI2 IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7C0 PSY UI97715
UP24/07/30 P F407
R7CJ PSY UI97716
UP24/07/30 P F407
R7D0 PSY UI97717
UP24/07/30 P F407
R7DJ PSY UI97718
UP24/07/30 P F407
R7E0 PSY UI97719
UP24/07/30 P F407
R7EJ PSY UI97720
UP24/07/30 P F407
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7E0","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: