  • A program compiles successfully using COBOL V6.2 but it fails in
    V6.3/V6.4 with the following messages:
    IGYPS5125-U   The compilation was terminated due to a compiler
    error in phase id:  "IGYCPSCN".
    IGYPS5306-U   An internal compiler error occurred.  Condition
    (GITTYPCD=GITTYPCV&GITC1ST=ON) failed at IGYQPR04-32768
    
    ADDITIONAL SYMPTOMS:
    IGYPS5125-U, IGYPS5306-U
    

Local fix

  • BYPASS/CIRCUMVENTION:
    None
    
    RECOVERY ACTION:
    Apply PTF
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling     *
    *                 programs that contain a SPECIAL-NAMES        *
    *                 paragraph that defines one or more 1-byte    *
    *                 user-programmable status indicator (UPSI)    *
    *                 switches.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Compiler abort with message:            *
    *                                                              *
    *                      IGYPS5125-U   The compilation was       *
    *                      terminated due to a compiler error      *
    *                      in phase id:  "IGYCPSCN".               *
    *                                                              *
    *                      IGYPS5201-U   Internal compiler error   *
    *                      code "QPR04-00" occurred.               *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM provided PTF and rerun the     *
    *                 compile.                                     *
    ****************************************************************
    There was a null pointer dereference in the compiler when
    handling a SPECIAL-NAMES paragraph with one or more 1-byte
    user-programmable status indicator (UPSI) switches.
    

Problem conclusion

  • The compiler was updated so that the null pointer dereference is
    avoided when there is a SPECIAL-NAMES paragraph with one or more
    1-byte user-programmable status indicator (UPSI) switches.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH61875

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-06-14

  • Closed date

    2024-06-14

  • Last modified date

    2024-07-01

  • APAR is sysrouted FROM one or more of the following:

    PH61120

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN
    IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD
    IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8
    IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK
    IGYMSGT  IGYQCBE  IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI97343

       UP24/06/28 P F406

  • R621 PSY UI97344

       UP24/06/28 P F406

  • R622 PSY UI97345

       UP24/06/28 P F406

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date:
02 July 2024