A fix is available
APAR status
Closed as program error.
Error description
A program compiles successfully using COBOL V6.2 but it fails in V6.3/V6.4 with the following messages: IGYPS5125-U The compilation was terminated due to a compiler error in phase id: "IGYCPSCN". IGYPS5306-U An internal compiler error occurred. Condition (GITTYPCD=GITTYPCV&GITC1ST=ON) failed at IGYQPR04-32768 ADDITIONAL SYMPTOMS: IGYPS5125-U, IGYPS5306-U
Local fix
BYPASS/CIRCUMVENTION: None RECOVERY ACTION: Apply PTF
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.3 compiling * * programs that contain a SPECIAL-NAMES * * paragraph that defines one or more 1-byte * * user-programmable status indicator (UPSI) * * switches. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abort with message: * * * * IGYPS5125-U The compilation was * * terminated due to a compiler error * * in phase id: "IGYCPSCN". * * * * IGYPS5201-U Internal compiler error * * code "QPR04-00" occurred. * **************************************************************** * RECOMMENDATION: Apply the IBM provided PTF and rerun the * * compile. * **************************************************************** There was a null pointer dereference in the compiler when handling a SPECIAL-NAMES paragraph with one or more 1-byte user-programmable status indicator (UPSI) switches.
Problem conclusion
The compiler was updated so that the null pointer dereference is avoided when there is a SPECIAL-NAMES paragraph with one or more 1-byte user-programmable status indicator (UPSI) switches.
Temporary fix
Comments
APAR Information
APAR number
PH61120
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-04-29
Closed date
2024-05-14
Last modified date
2024-06-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI96895
UP24/05/30 P F405
R631 PSY UI96896
UP24/05/30 P F405
R632 PSY UI96897
UP24/05/30 P F405
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: