Error description

  • You migrate to CICS TS 6.1 and start receiving ABENDATCE
    which means- no tioa was supplied for a write request.
    
    Looking at a system dump from the ATCE abend, CICS trace
    shows the abend is occurring on the first
    EXEC CICS RECEIVE-TC
    command issued by the task. Here are the trace entries:
    AP 00E1 EIP ENTRY RECEIVE-TC
    AP FD01 ZARQ ENTRY APPL_REQ TCTTE(22D33AB0) READ WAIT READBUF
                       TRANSPARENT
    AP 2000 PCPG ENTRY - ABEND
    
    Looking at the code in DFHZARQ at the 6.1 level, there is new
    code added to check for the presence of a Terminal Input
    Ouput Area or TIOA, if auto journaling is turned on.
    In this case, there is no TIOA which leads to the ATCE abend.
    
    This check for the TIOA was not made in the prior release of
    CICS.
    
    Additional symptoms: KIXREVRJL
    DBUG terminal initiated journal attributes autojournal
    

Local fix

  • turn off journaling in the terminal profile associated with the
    transaction
    

Problem summary

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH60509

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    400

  • Status

    OPEN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-03-22

  • Closed date

  • Last modified date

    2024-04-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 April 2024