A fix is available
APAR status
Closed as program error.
Error description
You are signing onto a CPSM WUI ( CICSPlex SM Web User Interface ) browser with a userid that utilizes Multi-Factor Authentication. At the same time you are signing on, you are also trying to change your password. You enter the correct current password and valid new password, and get an error message stating your password is invalid. But your password was successfully changed to your new one. If you then attempt to sign on using the new password, it is successful. If you capture an SVC dump of the WUI region with CICS trace turned on, all components at 1 except EI and XS both at '1-2', you'll see trace entries for EXEC CICS CHANGE PHRASE (successful) followed by an entry for EXEC CICS VERIFY PHRASE which fails, and the following exception trace is made: XS FE04 XSSB *EXC* FUNCTION(INQUIRE_PASSWORD_DATA) RESPONSE(EXCEPTION) REASON(INVALID_PASSWORD) SAF_RESPONSE(8) SAF_REASON(0) ESM_RESPONSE(8) ESM_REASON(0)
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM Users * **************************************************************** * PROBLEM DESCRIPTION: The CPSM WUI incorrectly reports * * EYUVC1030E when changing a password * * or password phrase for a user id * * configured with Multi-factor * * Authentication (MFA). * **************************************************************** * RECOMMENDATION: The PTFs addressing this APAR should be * * applied to all WUI regions. * **************************************************************** When changing the password/password phrase of a user id using the CPSM WUI application, after the change the user is logged into the WUI, with days until password expire and last log in date/time being displayed. These are output in message EYUVC1000 on a successful login, after a the change is complete. However, when a user employing MFA or other forms of one-time password, uses the WUI to change password/pass phrase, the change completes successfully. However to complete the login process and extract the other details displayed the WUI performs a CICS VERIFY call with the new password without an MFA token which fails. This failure causes the WUI to abort the login and produce message: EYUVC1030E Invalid user name or password. Try again. This is produce even though the password/pass phrase has been successfully changed. Additional Keywords: PH59546 PH59547
Problem conclusion
The WUI processing for change user password or pass phrase has been updated to extract LASTUSETIME and DAYSLEFT values, which are returned on successful login, from the CHANGE PHRASE call. Allowing the WUI to successfully complete login in this described scenario.
Temporary fix
Comments
APAR Information
APAR number
PH59574
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
20M
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-02-01
Closed date
2024-05-14
Last modified date
2024-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PH60714 UI96888 UI96889
Modules/Macros
EYU0VPSN
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.