A fix is available
APAR status
Closed as program error.
Error description
The compiler front end doesn't properly represent ADDRESS OF parameters to various intrinsic functions like BIT-OF and HEX-OF in the intermediate language, leading to the back end assertion in WCodezOSSystemOSLinkage.
Local fix
Set a pointer to the ADDRESS OF some-item, and use the pointer in the function call.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.4 compiling * * programs that contain an invocation of the * * HEX-OF or BIT-OF intrinsic function with an * * argument of the form "ADDRESS OF * * identifier-1", where identifier-1 refers to * * a COBOL data item defined as an unbounded * * table. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abort, with message: Assertion * * failed at * * ilgen/z/WCodezOSSystemOSLinkage.cpp: * * 2916: _parentDSASymRef != NULL * * _parentDSASymRef not established * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** When the argument of the HEX-OF/BIT-OF intrinsic function was of the form ADDRESS OF <unbounded table>", the compiler was inadvertently treating the result value as being dynamic in length instead of having a fixed length.
Problem conclusion
The compiler was updated so that when an argument of the form "ADDRESS OF <unbounded table>" is used in the HEX-OF/BIT-OF intrinsic function, the result value is understood to be fixed in length.
Temporary fix
Comments
APAR Information
APAR number
PH59549
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-02-01
Closed date
2024-02-13
Last modified date
2024-03-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWRD IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJBLD IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R640 PSY UI95661
UP24/02/27 P F402
R641 PSY UI95662
UP24/02/27 P F402
R642 PSY UI95663
UP24/02/27 P F402
R64H PSY UI95664
UP24/02/27 P F402
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.