A fix is available
APAR status
Closed as program error.
Error description
A serviceability improvement of the tracing for IPIC CIST and CISD transactions.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: Improve diagnostics for IPCONN in a * * FREEING state. * **************************************************************** When an IPIC connection is RELEASED it will enter a FREEING state until the tasks running through the connection have completed. With the current diagnostics it is difficult to identify which tasks the IPCONN is waiting on.
Problem conclusion
CICS has been changed so that a new trace entry is issued to display which tasks the IPCONN is waiting on when it is in a FREEING state.
Temporary fix
Comments
APAR Information
APAR number
PH59477
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-01-30
Closed date
2024-03-12
Last modified date
2024-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI96041
Modules/Macros
DFHCIS4 DFHISAL DFHISCO DFHISCOP DFHISCU DFHISDM DFHISDUF DFHISEM DFHISEMP DFHISFS DFHISIC DFHISIF DFHISIS DFHISJU DFHISLQ DFHISLQP DFHISPH DFHISPHP DFHISPRP DFHISRE DFHISRR DFHISRRP DFHISRS DFHISRSP DFHISSR DFHISST DFHISTRI DFHISUE DFHISXF DFHISXM DFHISXS DFHISZA DFHMIRS
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
R400 PSY UI96041
UP24/03/14 P F403
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: