IBM Support

PH58186: Compiler abends with message IGYCB7104-U Internal error while compiling xxx. Failed assertion on ilgen/WCodeSymbol.cpp:266.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Compiler abends with message IGYCB7104-U Internal error while
    compiling function xxxx. Failed assertion on
    ilgen/WCodeSymbol.cpp:266. Compilation terminated.
    
    ADDITIONAL SYMPTOMS:
    IGYCB7104-U
    
    
    
    
    
    
    
    
    
    
    
    
    
    
                                               x
    

Local fix

  • BYPASS/CIRCUMVENTION:
    None
    
    RECOVERY ACTION:
    Apply PTF
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling      *
    *                 programs at LP(64) that contain an SORT      *
    *                 statement with INPUT/OUTPUT PROCEDURE that   *
    *                 contain reference modified data item.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: Compiler abends with message            *
    *                      MSGIGYCB7104-U Internal error while     *
    *                      compiling function #SortProc_1.         *
    *                      Failed assertion on ilgen/              *
    *                      WCodeSymbol.cpp:266. Compilation        *
    *                      terminated.                             *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The compiler's internal state is wrong while compiling programs
    at LP(64) that contain an SORT statement with INPUT/OUTPUT
    PROCEDURE that contain reference modified data item.
    

Problem conclusion

  • The compiler's internal state is fixed while compiling programs
    at LP(64) that contain an SORT statement with INPUT/OUTPUT
    PROCEDURE that contain reference modified data item.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH58186

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-11-14

  • Closed date

    2024-01-26

  • Last modified date

    2024-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH58662 UI95428 UI95429 UI95430

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR
    IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1
    IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R
    IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE
    IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI95428

       UP24/01/31 P F401

  • R631 PSY UI95429

       UP24/01/31 P F401

  • R632 PSY UI95430

       UP24/01/31 P F401

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: