A fix is available
APAR status
Closed as program error.
Error description
Compiler abends with message IGYCB7104-U Internal error while compiling function xxxx. Failed assertion on ilgen/WCodeSymbol.cpp:266. Compilation terminated. ADDITIONAL SYMPTOMS: IGYCB7104-U x
Local fix
BYPASS/CIRCUMVENTION: None RECOVERY ACTION: Apply PTF
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling * * programs at LP(64) that contain an SORT * * statement with INPUT/OUTPUT PROCEDURE that * * contain reference modified data item. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abends with message * * MSGIGYCB7104-U Internal error while * * compiling function #SortProc_1. * * Failed assertion on ilgen/ * * WCodeSymbol.cpp:266. Compilation * * terminated. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The compiler's internal state is wrong while compiling programs at LP(64) that contain an SORT statement with INPUT/OUTPUT PROCEDURE that contain reference modified data item.
Problem conclusion
The compiler's internal state is fixed while compiling programs at LP(64) that contain an SORT statement with INPUT/OUTPUT PROCEDURE that contain reference modified data item.
Temporary fix
Comments
APAR Information
APAR number
PH58186
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-11-14
Closed date
2024-01-26
Last modified date
2024-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PH58662 UI95428 UI95429 UI95430
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI95428
UP24/01/31 P F401
R631 PSY UI95429
UP24/01/31 P F401
R632 PSY UI95430
UP24/01/31 P F401
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: