IBM Support

PH57994: EXITHLL PARAMETER MISSING FROM THE INZUTIL PARMLIB MEMBER

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • (HPU 5.2 only) The value of the EXITHLL parmlib parameter is not
    stored in the INZUTIL parmlib member which prevents a correct
    retrieval from the settings by the DISCOVER mechanism from
    Tools Customizer.
    

Local fix

  • none but, consider either of the following:
    
    - before using the parmlib as an input for the Tools Customizer
    DISCOVER feature, manually add a line with EXITHLL=value into
    the INZUTIL member from the parmlib
    - after using the parmlib as an input for the Tools Customizer
    DISCOVER feature, make sure to check the value of the
    VUU079/EXITHLL parmlib parameter and correct it if needed
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 High Performance Unload for     *
    *                 z/OS                                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: The value of the EXITHLL parmlib        *
    *                      parameter is not stored in the          *
    *                      INZUTIL parmlib member which prevents   *
    *                      a correct retrieval from the settings   *
    *                      by the DISCOVER mechanism from Tools    *
    *                      Customizer.                             *
    *                                                              *
    *                      Local fix: none but, consider either    *
    *                      of the following:                       *
    *                      - before using the parmlib as an input  *
    *                      for the Tools Customizer DISCOVER       *
    *                      feature, manually add a line with       *
    *                      EXITHLL=value into the INZUTIL member   *
    *                      from the parmlib                        *
    *                      - after using the parmlib as an input   *
    *                      for the Tools Customizer DISCOVER       *
    *                      feature, make sure to correct the       *
    *                      value of the EXITHLL parmlib parameter  *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF                                *
    ****************************************************************
    EXITHLL parameter missing from the INZUTIL parmlib member
    

Problem conclusion

  • Code has been changed to fix this problem
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH57994

  • Reported component name

    DB2 HI PERF UNL

  • Reported component ID

    5697F4400

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-11-03

  • Closed date

    2023-12-20

  • Last modified date

    2024-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • INZ$$PRM INZTDSC  INZTVAR  INZUTILK
    

Fix information

  • Fixed component name

    DB2 HI PERF UNL

  • Fixed component ID

    5697F4400

Applicable component levels

  • R520 PSY UI94933

       UP24/01/04 P F401

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
01 February 2024