A fix is available
APAR status
Closed as program error.
Error description
After applying PTF UI91933 or UI91934 or UI91935, an application loops indefinitely when opening a clustered object in a Partial Repository Queue Manager.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM MQ for z/OS Version 9 * * Release 1 Modification 0 and * * Release 2 Modification 0 and * * Release 3 Modification 0. * **************************************************************** * PROBLEM DESCRIPTION: An application loops indefinitely when * * opening a clustered object in a Partial * * Repository Queue Manager. * **************************************************************** A timing window exists where if a batch application opening a clustered object in a Partial Repository Queue Manager for the first time does so at the same time as the Channel Initiator Address space is stopped then the application can loop indefinitely.
Problem conclusion
The code has been corrected to remove the timing window causing the reported symptoms.
Temporary fix
Comments
APAR Information
APAR number
PH57713
Reported component name
IBM MQ Z/OS V9
Reported component ID
5655MQ900
Reported release
100
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-10-23
Closed date
2023-11-06
Last modified date
2023-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI94302 UI94303 UI94304
Modules/Macros
CSQMZLOO
Fix information
Fixed component name
IBM MQ Z/OS V9
Fixed component ID
5655MQ900
Applicable component levels
R100 PSY UI94304
UP23/11/21 P F311 {
R200 PSY UI94303
UP23/11/16 P F311 {
R300 PSY UI94302
UP23/11/16 P F311 {
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"100","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: