IBM Support

PH57688: INCORRECT STATEMENT NUMBER IN CEEDUMP WITH OPT(1) AND OPT(2)

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Traceback information in a CEEDUMP may provide an incorrect
    statement number in reference to a COBOL program.
    

Local fix

  • Compile with OPT(0)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.4 compiling      *
    *                 programs at OPT(1|2) and containing at       *
    *                 least two MOVE statements where the senders  *
    *                 are smaller than the receivers, the first    *
    *                 MOVE is either not a reference modification  *
    *                 or is a reference modification where the     *
    *                 start and length are literals, and at least  *
    *                 one of the start and length in the second    *
    *                 MOVE are data items.                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: An LHI instruction generated for the    *
    *                      second MOVE has the line number of the  *
    *                      first MOVE statement.                   *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF                       *
    ****************************************************************
    Generation of the LHI Instruction in the first MOVE statement
    is postponed to the second MOVE statement, leading to a
    different line number assigned to the instruction.
    

Problem conclusion

  • The compiler was fixed to update the line number in above case.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH57688

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    640

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-10-20

  • Closed date

    2023-10-23

  • Last modified date

    2023-11-01

  • APAR is sysrouted FROM one or more of the following:

    PH56614

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1
    IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL
    IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0
    IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D
    IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT
    IGYQCBE  IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R640 PSY UI94116

       UP23/11/01 P F310

  • R641 PSY UI94117

       UP23/11/01 P F310

  • R642 PSY UI94118

       UP23/11/01 P F310

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: