A fix is available
APAR status
Closed as program error.
Error description
If an exception occurs in a CALL "Java..." but there's no ON EXCEPTION clause, the cjbuild generated code will do a STOP RUN, but fail to set the RETURN-CODE first. Because STOP RUN is a "normal" form of completion rather than an exception, the local RETURN-CODE, which is likely to be zero, becomes the condition code returned from the enclave/step, obscuring the underlying failure.
Local fix
Modify the generated code to set the RETURN-CODE before STOP RUN statements.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.4 compiling and * * running programs that make calls to static * * Java methods using the CALL statement but * * don't use the ON EXCEPTION phase of the CALL * * statement. * **************************************************************** * PROBLEM DESCRIPTION: When an exception is encountered during * * a call to Java using the CALL * * statement, the run unit is stopped as * * expected, but the RETURN-CODE special * * register is not set to 16 to indicate a * * non-recoverable error. * **************************************************************** * RECOMMENDATION: Apply the IBM-provided PTF * **************************************************************** The stub program generated for calls from COBOL to Java was not setting the RETURN-CODE special register to 16 before issuing STOP RUN in the case where an exception is detected during the CALL and the ON EXCEPTION phrase of the CALL statement was not specified.
Problem conclusion
The compiler was updated to ensure that the RETURN-CODE special register is set to 16 before issuing a STOP RUN in a stub program for a call from COBOL to Java.
Temporary fix
Comments
APAR Information
APAR number
PH57329
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-10-03
Closed date
2023-10-23
Last modified date
2023-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R640 PSY UI94116
UP23/11/01 P F310
R641 PSY UI94117
UP23/11/01 P F310
R642 PSY UI94118
UP23/11/01 P F310
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: