IBM Support

PH57197: ISPT034 TABLE IS NOT OPEN ERROR IN ADB28SC JOB TBBOTTOM ISSUED FOR TABLE ADB28XCL THAT IS NOT OPEN CC 990

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If MIGVARS dataset does not have ADB28XCL member then ADB28SC
    job (REDEFINE SCOPE OF MIG) fails with "ISPT034 Table is not
    open. TBBOTTOM issued for table ADB28XCL that is not open" error
     CC 990
    

Local fix

  • Use MIG on any database object to initialize MIGVARS dataset.
    This will create ADB28XCL in it and then they can use it in
    ADBMGSC job.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 Administration Tool for z/OS    *
    ****************************************************************
    * PROBLEM DESCRIPTION: REDEFINE SCOPE OF MIG job fails with    *
    *                      ISPT034 error.                          *
    ****************************************************************
    When the MIGVARS data set used in the REDEFINE SCOPE OF MIG job
    does not have an ADB28XCL member, the following error occurs:
    'ISPT034 Table is not open error in ADB28SC job TBBOTTOM issued
    for table ADB28XCL that is not open'.
    

Problem conclusion

  • The problem has been resolved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH57197

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    D10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-09-27

  • Closed date

    2024-01-16

  • Last modified date

    2024-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI95244 UI95245

Modules/Macros

  • ADB28SC
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RC10 PSY UI95244

       UP24/01/18 P F401

  • RD10 PSY UI95245

       UP24/01/18 P F401

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: