A fix is available
APAR status
Closed as program error.
Error description
Error message IGYCB7104-U may be issued when compiling COBOL program when compiling with NUMCHECK.
Local fix
Compile with NONUMCHECK
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.2 compiling * * programs with NUMCHECK that have secondary * * entry points and have data items in * * LOCAL-STORAGE that are of a type checked by * * NUMCHECK and that are referenced in the * * PROCEDURE DIVISION in a location that is * * reachable from one or more secondary entry * * points. * **************************************************************** * PROBLEM DESCRIPTION: Enterprise COBOL Compiler terminated * * with message MSGIGYCB7104-U Internal * * error while compiling program * * XXXXXXXX. Failed assertion on * * ilgen/NSEPChecker.cpp:360. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** While finding the addresses of data items relative to the start of a secondary entry point, the compiler was abending when checking data items that are both in LOCAL-STORAGE and are checked by NUMCHECK.
Problem conclusion
The compiler no longer abends when finding the addresses of data items relative to the start of a secondary entry point for items that are both in LOCAL-STORAGE and are checked by NUMCHECK.
Temporary fix
Comments
APAR Information
APAR number
PH56950
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-09-14
Closed date
2023-09-15
Last modified date
2023-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI93578
UP23/09/23 P F309
R621 PSY UI93579
UP23/09/23 P F309
R622 PSY UI93580
UP23/09/23 P F309
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 October 2023