A fix is available
APAR status
Closed as program error.
Error description
With optimization, for a program RETURNING a datatype that can't be returned in a register, typically something not a simple binary or floating point type, and ending with a STOP RUN rather than a GOBACK, the compiler fails: IGYCB7104-U Internal error while compiling program {program}. Failed assertion on ... /il/Node.hpp:1368. Compilation terminated.
Local fix
Use a GOBACK
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.x compiling * * programs at OPT(1|2) that contain a STOP * * RUN statement and return a data item of any * * type besides binary and floating point. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abend with message * * MSGIGYCB7104-U Internal error while * * compiling program XXXXXX. Failed * * assertion on * * /build/cob/6.4/ * * tr.v64.cobol-prod-opt/tr.source/ibm/il/ * * Node.hpp:1368. Compilation terminated. * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** The compiler's internal state may become inaccurate when compiling programs at OPT(1|2) that return a data item that isn't binary or floating point and have a STOP RUN statement. When the compiler detects that its internal state is inaccurate, it abends.
Problem conclusion
The compiler was fixed to update its internal state correctly.
Temporary fix
Comments
APAR Information
APAR number
PH56949
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-09-14
Closed date
2023-09-15
Last modified date
2023-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI93578
UP23/09/23 P F309
R621 PSY UI93579
UP23/09/23 P F309
R622 PSY UI93580
UP23/09/23 P F309
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 October 2023