A fix is available
APAR status
Closed as program error.
Error description
BPE0003E AN ERROR OCCURRED PARSING CONFIGURATION MEMBER BPE0003E CHARACTER VALUE WAS TOO LONG FOR PARAMETER when symbolic used in DSN. DRF expects the area specified by DSN= to be 44 characters or less. It does not take into account that the DSN name does not exceed 44 characters after the symbolic parameters are expanded.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS Recovery Solution Pack for z/OS * * Version 2 Release 1 ( FMID=HAHM210 ) * * IMS Database Recovery Facility users. * **************************************************************** * PROBLEM DESCRIPTION: When symbolic used in DSN, DRF expects * * the area specified by DSN= to be 44 * * characters or less. It does not take * * into account that the DSN name does not * * exceed 44 characters after the symbolic * * parameters are expanded. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** A DRF job with an ADD IC command ended with message FRD6140A after a BPE error message BPE0003E was issued. The output image copy data set name contains 49 characters. However, the data set name that DRF allocates for the integrated auxiliary utility parameters for IMS HP Image Copy is 44 characters, which resulted in the BPE error.
Problem conclusion
For integrated auxiliary utility parameters for IMS HP Image Copy, DSN parameter has been expanded from 44 characters to 54 characters, and DSN2 parameter has been expanded from 44 characters to 53 characters in accordance with the integrated auxiliary utility parameters for IMS HP Image Copy restrictions.
Temporary fix
Comments
APAR Information
APAR number
PH56771
Reported component name
IMS RCVR SOLUTN
Reported component ID
5655V8600
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-09-06
Closed date
2023-10-24
Last modified date
2023-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI94137
Modules/Macros
FRXEDRF0 FRXEPSS0 FRXLBLD0 FRXMSTR0 FRXSDR00 FRXTAU00 FRXUAPI0 FRXVCMD0 FRXVSTA1 FRXVSTA3
SC27844108 |
Fix information
Fixed component name
IMS RCVR SOLUTN
Fixed component ID
5655V8600
Applicable component levels
R210 PSY UI94137
UP23/10/26 P F310
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"2.1.0"}]
Document Information
Modified date: