Error description
The compiler is failing in PHASE: IGYCASMB issuing the following messages: nnnnnn IGYAS5125-U The compilation was terminated due to a compiler error in phase id: "IGYCASMB". nnnnnn IGYAS5295-U The compilation failed due to an internal error detected in the compiler back-end. The error code was 267.
Local fix
BYPASS/CIRCUMVENTION: If OPT(0),NOINITCHECK are used, the compile is successful.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling * * programs with OPT(0), INITCHECK(LAX|STRICT) * * that contain unreachable "EXEC CICS HANDLE" * * statements. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abend with message * * MSGIGYAS5125-U The compilation was * * terminated due to a compiler error in * * phase id: "IGYCASMB" * * and message MSGIGYAS5295-U The * * compilation failed due to an internal * * error detected in the compiler * * back-end. The error code was 267. * **************************************************************** * RECOMMENDATION: Compile at OPT(1) or higher, or with * * NOINITCHECK, or remove the unreachable EXEC * * CICS HANDLE code * **************************************************************** The compiler's internal state became incorrect when analyzing CICS statements, leading to an an abend.
Problem conclusion
The compiler was fixed to keep its internal state valid when analyzing CICS statementts.
Temporary fix
Comments
APAR Information
APAR number
PH54553
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-05-16
Closed date
2023-05-16
Last modified date
2023-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI91831
UP23/05/26 P F305
R631 PSY UI91832
UP23/05/26 P F305
R632 PSY UI91833
UP23/05/26 P F305
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023