IBM Support

PH54425: SYNTAX ERRORS DURING BUILDING A COBOL PROGRAM WHICH HAS AN INCLUDE STATEMENT WITHIN THE EXEC SQL BLOCK

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Application Discovery Build Client gives syntax errors when
    building a COBOL program which has an INCLUDE statement within
    an EXEC SQL block as below.
    EXEC SQL
        INCLUDE <Include file name>
    END-EXEC.
    

Local fix

  • N/A
    

Problem summary

  • AD COBOL compiler would not correctly parse the INCLUDE
    statement in an EXEC SQL if there there is a COBOL variable
    defined called "INCLUDE". A "Warning [999] : Syntax error:
    'INCLUDE'" is displayed in the output window.
    

Problem conclusion

  • Fixed by treating the INCLUDE statement as a statement and not
    as a COBOL variable for this specific scenario.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH54425

  • Reported component name

    APPL DISCOVERY

  • Reported component ID

    5737B1600

  • Reported release

    611

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-05-09

  • Closed date

    2023-05-25

  • Last modified date

    2023-05-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APPL DISCOVERY

  • Fixed component ID

    5737B1600

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRR9Q","label":"IBM Application Discovery"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"611","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: