A fix is available
APAR status
Closed as program error.
Error description
A CICS region is using dummy MVS logstreams with an INITIAL start specified. CICS is cancelled with /C jobname,ARMRESTART, and comes down as expected. ARM then restarts the region. But CICS will ignore the SIT or overrides for an INITIAL start and force an AUTO restart (i.e. EMERGENCY in this case) because this is an ARM restart with RESTART_METHOD=PERSISTENT. Because CICS doesn't come up INITIAL, when CICS tries to read the logs, the lack of logs causes the restart to fail with message: DFHRM0401 There is no system log or an empty system log has been detected. Additional Symptom(s) Search Keyword(s): AUTOINIT DFHRMUTL
Local fix
Do not use persistent JCL for ARM in the restart_method defined for CICS in the ARM policy.
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: A CICS system restarted by ARM using * * persistent JCL fails with message * * DFHRM0401. * **************************************************************** The CICS subsystem can be registered with automatic restart manager (ARM) to be restarted automatically if it fails in an uncontrolled manner. The ARM policy identifies elements and restart groups with restart parameter values. If the CICS system logs are defined to be DUMMY, CICS regions can only be INITIAL started.However, when the ARM policy is defined to use persistent JCL on restart and extended recovery facility (XRF) is not used, then the CICS start type is forced to be AUTO. The restart then fails with ABEND U1800 and a DFHRM0401 message indicating an empty system log has been detected on a CICS restart which requires the log for recovery processing.
Problem conclusion
CICS has been changed to issue a new message DFHKE0415 to inform the user that CICS will restart with start type AUTO. The CICS Messages manual will be updated with the following new message: DFHKE0415 <APPLID> CICS IS BEING RESTARTED WITH PERSISTENT JCL AND XRF=NO. CICS WILL RESTART WITH TYPE=AUTO. Explanation: An attempt to invoke a REGISTER request against the z/OS automatic restart manager (ARM) has succeeded. However, the system is being restarted with persistent JCL and without extended recovery facility (XRF). Any override for CICS start type from the JCL is ignored and forced to be AUTO. Note that any CICS regions using DUMMY system logs will fail to restart with message DFHRM0401. This is an informational message. System action: Restart continues. User response: None. Module: DFHKEAR
Temporary fix
Comments
APAR Information
APAR number
PH53620
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-03-30
Closed date
2023-08-31
Last modified date
2023-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI93406
Modules/Macros
DFHKEAR DFHMEKEC DFHMEKEE DFHMEKEK
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
R400 PSY UI93406
UP23/09/06 P F309
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 October 2023