IBM Support

PH53590: ABEND0C4 OR ABENDC78-04 CQM$ACTA IN VIEW CURRENT ACTIVITY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Intermittent Abend0C4 or AbendC78-04 seen when Current Activity
    display exceeds many, many rows depending on TSO USER regions
    size.
    

Local fix

  • When problem occurs exit the CQM ISPF dialog and go back in.
    Exiting will clean up the storage for that task
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Db2 Query Monitor and TCz       *
    ****************************************************************
    1. Row formatting defect that could break the cell pool
    structure causing unnecessary extends that could result in
    storage exhaustion
    2. Db2 13 selection in TCz was inadvertently invalidated
    

Problem conclusion

  • 1. For display row formatting the incorrect clearing length was
    resolved to the proper length, thus keeping the cell pool
    construction intact.
    2. Re-enable Db2 13 as a selection in the Db2 Tools Customizer
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH53590

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    330

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-03-29

  • Closed date

    2023-07-03

  • Last modified date

    2023-07-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI92577

Modules/Macros

  • CQM      CQM$$CCQ CQM$ACTV CQM$GPOB CQM$GPOV CQM$LC27 CQM$PRGI
    CQM34    CQM35    CQM359E  CQM36    CQM367E  CQM85    CQM853E
    CQMCLIST CQMCLST1 CQMHGPOB CQMHLC18 CQMHPRGI
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R330 PSY UI92577

       UP23/07/06 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.