IBM Support

PH53543: ABO FAILED ASSERTION BINDER.CPP:7550

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABO Failed Assertion Binder.cpp:7550
    

Local fix

  • BYPASS/CIRCUMVENTION:
    None
    
    RECOVERY ACTION:
    Apply PTF
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Automatic Binary Optimizer      *
    *                 (ABO) for z/OS, 2.2 and ABO for z/OS 2.2     *
    *                 Trial                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: In rare cases, ABO may fail with the    *
    *                      "Assertion failed at ./Binder.cpp:7550: *
    *                      false" message when optimizing COBOL    *
    *                      programs compiled with the TEST option. *
    *                      This happens due to ABO being unable to *
    *                      generate new DWARF debug data for the   *
    *                      optimized program in some situations    *
    *                      where the original instruction          *
    *                      referenced by the DWARF data was        *
    *                      removed.                                *
    ****************************************************************
    * RECOMMENDATION: Apply provided service                       *
    ****************************************************************
    ABO was modified to generate placeholder DWARF data in cases
    where ABO removes instructions and the corresponding DWARF data
    is retained.
    

Problem conclusion

  • ABO was modified to correctly optimize input modules with these
    types of DWARF data.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH53543

  • Reported component name

    AUTO BINARY OPT

  • Reported component ID

    5697AB200

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-03-28

  • Closed date

    2023-04-13

  • Last modified date

    2023-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • BOZBXITA BOZEXE1  BOZGLUE  BOZJIVP  BOZMSGE  BOZMSGK  BOZMSGT
    BOZOBJ1  BOZOBJ2  BOZOPT   BOZPA    BOZPAJ   BOZRIDT  BOZSETRT
    BOZSMF   BOZSMFJ  BOZSMFR  BOZSRC1  BOZSRC2  BOZTRUE
    

Fix information

  • Fixed component name

    AUTO BINARY OPT

  • Fixed component ID

    5697AB200

Applicable component levels

  • R220 PSY UI91439

       UP23/04/15 P F304

  • R22J PSY UI91440

       UP23/04/15 P F304

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.