Error description
SQL Apply failed with asn1001e for event based subscription.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: 1- Users running db2 V13 * * 2- All Q Capture users * * 3- ALL Q Capture users * * 4- All SQL Apply users * **************************************************************** * PROBLEM DESCRIPTION: 1- SQL Capture should have the * * IFI_FILTER_PARTS parameter, which * * already exists for Q Capture. * * 2- Need more diagnostic data for ICU * * error in Q Capture * * 3- Q Capture failed when building the * * decode base * * 4- SQL Apply failed with asn1001e for * * event based subscription. * **************************************************************** 1- The IFI_FILTER_PARTS parameter needs to be added to SQL Capture as a command line parameter and in the IBMSNAP_CAPPARMS table, to support IFI filtering by tablespace and partition range. 2- Q Capture should display the data being converted when an ICU error occurs. Also, ASN0606I should be written to the stdout, regardless of the setting of capture parameter LOGSTDOUT 3- Q Capture ABEND0C4 during initialization 4- The SQL statement issued by SQL Apply to fetch the synchpoint failed with SQLCODE -104 due to extra closing bracket.
Problem conclusion
1- The IFI_FILTER_PARTS parameter is added to SQL Capture. The default is Y for V13, and N for V12. 2- Q Capture is changed to issue a diagnostic message with the data being converted when an ICU error occurs. Also fixed the destination problem for ASN0606I message. 3- During Q Capture initialization, if the version table does not mach the system catalog and CAPSTART_REORGCHECK=N and Db2 supports converting the log records, Q Capture will activate the subscription. Otherwise the subscription will be failed. 4- Apply is changed to remove the extra closing bracket that causes the error Note: ASNCLP has been updated from v1158 s2305031135. Function Level: 1140.103
Temporary fix
Comments
APAR Information
APAR number
PH53246
Reported component name
WS REPLICATION
Reported component ID
5655L8800
Reported release
B33
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-03-14
Closed date
2023-05-10
Last modified date
2023-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI91749 UI91750 UI91751 UI91752
Modules/Macros
ASN2BASE ASN2SQLZ ASNACMD ASNADMSP ASNAISO ASNAPPLY ASNCAP ASNCATM ASNCCMD ASNCCPWK ASNCDINS ASNCLPAP ASNCLPCL ASNCLPCM ASNCLPCO ASNCLPMS ASNCLPQA ASNMCMD ASNMON ASNQACMD ASNQAPP ASNQCAP ASNQCCMD ASNQDEP ASNQEXRP ASNQMFMT ASNQXFMT ASNRBASE ASNSQLCZ ASNTDIFF ASNTDSP ASNTRC
Fix information
Fixed component name
WS REPLICATION
Fixed component ID
5655L8800
Applicable component levels
RB33 PSY UI91749
UP23/05/17 P F305
RB34 PSY UI91750
UP23/05/18 P F305
RB35 PSY UI91751
UP23/05/17 P F305
RB36 PSY UI91752
UP23/05/17 P F305
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O","label":"InfoSphere Replication Server"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B33"}]
Document Information
Modified date:
01 June 2023