Error description

  • SQL Apply failed with asn1001e for event based subscription.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: 1- Users running db2 V13                     *
    *                 2- All Q Capture users                       *
    *                 3- ALL Q Capture users                       *
    *                 4- All SQL Apply users                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1- SQL Capture should have the          *
    *                      IFI_FILTER_PARTS parameter, which       *
    *                      already exists for Q Capture.           *
    *                      2- Need more diagnostic data for ICU    *
    *                      error in Q Capture                      *
    *                      3- Q Capture failed when building the   *
    *                      decode base                             *
    *                      4- SQL Apply failed with asn1001e for   *
    *                      event based subscription.               *
    ****************************************************************
    1- The IFI_FILTER_PARTS parameter needs to be added to SQL
    Capture as a command line parameter and in the IBMSNAP_CAPPARMS
    table, to support IFI filtering by tablespace and partition
    range.
    2- Q Capture should display the data being converted when an
    ICU error occurs. Also, ASN0606I should be written to the
    stdout, regardless of the setting of capture parameter LOGSTDOUT
    3- Q Capture ABEND0C4 during initialization
    4- The SQL statement issued by SQL Apply to fetch the
    synchpoint failed with SQLCODE -104 due to extra closing
    bracket.
    

Problem conclusion

  • 1- The IFI_FILTER_PARTS parameter is added to SQL Capture. The
    default is Y for V13, and N for V12.
    2- Q Capture is changed to issue a diagnostic message with the
    data being converted when an ICU error occurs. Also fixed the
    destination problem for ASN0606I message.
    3- During Q Capture initialization, if the version table does
    not mach the system catalog and CAPSTART_REORGCHECK=N and Db2
    supports converting the log records, Q Capture will activate
    the subscription. Otherwise the subscription will be failed.
    4- Apply is changed to remove the extra closing bracket that
    causes the error
    Note: ASNCLP has been updated from v1158 s2305031135.
    Function Level: 1140.103
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH53246

  • Reported component name

    WS REPLICATION

  • Reported component ID

    5655L8800

  • Reported release

    B33

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-03-14

  • Closed date

    2023-05-10

  • Last modified date

    2023-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI91749 UI91750 UI91751 UI91752

Modules/Macros

  • ASN2BASE ASN2SQLZ ASNACMD  ASNADMSP ASNAISO  ASNAPPLY ASNCAP
    ASNCATM  ASNCCMD  ASNCCPWK ASNCDINS ASNCLPAP ASNCLPCL ASNCLPCM
    ASNCLPCO ASNCLPMS ASNCLPQA ASNMCMD  ASNMON   ASNQACMD ASNQAPP
    ASNQCAP  ASNQCCMD ASNQDEP  ASNQEXRP ASNQMFMT ASNQXFMT ASNRBASE
    ASNSQLCZ ASNTDIFF ASNTDSP  ASNTRC
    

Fix information

  • Fixed component name

    WS REPLICATION

  • Fixed component ID

    5655L8800

Applicable component levels

  • RB33 PSY UI91749

       UP23/05/17 P F305

  • RB34 PSY UI91750

       UP23/05/18 P F305

  • RB35 PSY UI91751

       UP23/05/17 P F305

  • RB36 PSY UI91752

       UP23/05/17 P F305

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O","label":"InfoSphere Replication Server"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B33"}]

Document Information

Modified date:
01 June 2023