A fix is available
APAR status
Closed as program error.
Error description
During upgrade to 6.1 a few MAS regions were quiesced in COSM WLM. There were several messages to indicate it had been requested but never any message that it had completed. The workload was marked Frozen in the 6.1 CMAS. The job log of this CMAS shows the it was imported from another 6.1 CMAS as a frozen workload: date time EYUWM0412I applid Workload (workload) from context (plexname) has been Frozen while importing from CMAS1. In the other CMAS joblog we see message confirming it was frozen: date time EYUWM0412I applid Workload (workload) from context (plexname) has been Frozen due to loss of contact with CMAS2. This EYUWM0412I message is written when either a CMAS or MAS has terminated while the workload was active on either type of region, or a CMAS that is being joined to an existing workload has recognized that the workload is currently in a frozen state.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM Users. * **************************************************************** * PROBLEM DESCRIPTION: Workloads may incorrectly show as * * frozen on CMAS regions participating * * in a workload after the down regions * * have been restored. * **************************************************************** * RECOMMENDATION: After applying the PTF that resolves this * * APAR, all CMAS regions must be restarted. * * These restarts may occur in any order. . * **************************************************************** When a CMAS which has connected MAS regions participating in a workload is stopped, these regions are marked as lostcon (in the associated WAOR/WTORs), and the workload is frozen. If a another CMAS has its first target region in a workload start, it will attempt to import the existing workload from another active CMAS participating. If the down CMAS restarts during this import process (after the other CMAS has exported its workload state), the status of affected MAS in the imported workload information may be out of sync with the local Topology data held in the importing CMAS. This causes the workload freeze count(WRKD_FREEZE_CNT) to include the previous lostcon MAS regions. When the WAOR and WTOR values are being imported from the WRKQ, the import process in EYU0WMQU, due to the previous lostcon state, the local WTOR and WAOR values have the lostcon flag set, and then attempts to update topology for these regions. This calls TSNC to update topology, which fails. This results in a mismatch between the workload and topology for these regions. As such, the workload remains frozen incorrectly, due to the count not being able to be reduced for these AOR/TORs. This results in a mismatch between CMAS regions in the workload being frozen.
Problem conclusion
Workload import processing in EYU0WMQU has been corrected, to reconcile the incoming workload state for the WAOR/WTORs with the local topology state. This correctly reconciles the freeze count (WRKD_FREEZE_CNT) for active/lostcon MASes during import, and correctly freezes/defrosts the workload during import.
Temporary fix
Comments
APAR Information
APAR number
PH52540
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
40M
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / CST / Xsystem
Submitted date
2023-02-10
Closed date
2023-04-24
Last modified date
2023-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI91537 PH55985
Modules/Macros
EYU0WMQU
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
R40M PSY UI91537
UP23/04/28 P F304
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: