A fix is available
APAR status
Closed as program error.
Error description
IGYCB7104-U Failed assertion on ./BCDVectorSimplifier.cpp:588 at OPT(1)
Local fix
BYPASS/CIRCUMVENTION: Compile using OPT(0) RECOVERY ACTION: Apply PTF
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL compiling * * programs with OPT(1|2) and ARCH(12+) that * * contain COMPUTE or DIVIDE verbs that do * * division on PACKED-DECIMAL senders and the * * dividend has fewer digits to the right of * * the decimal place than the divisor * **************************************************************** * PROBLEM DESCRIPTION: Compiler abend with msg MSGIGYCB7104-U * * Internal error while compiling function * * XXXXX. Failed assertion on ./BCDVector * * Simplifier.cpp:588 * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** The compiler's internal state was incorrect when the dividend has fewer digits to the right of the decimal place than the divisor, and the compiler abended when it detected that its internal state was incorrect.
Problem conclusion
The compiler was fixed to have correct internal state when the dividend has fewer digits to the right of the decimal place than the divisor.
Temporary fix
Comments
APAR Information
APAR number
PH51966
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-01-17
Closed date
2023-01-23
Last modified date
2023-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJBLD IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R640 PSY UI90218
UP23/01/26 P F301
R641 PSY UI90219
UP23/01/26 P F301
R642 PSY UI90220
UP23/01/26 P F301
R64H PSY UI90221
UP23/01/26 P F301
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: