A fix is available
APAR status
Closed as program error.
Error description
If you set the Resolve Recover/Rebuild Pending Objects field to Y in the Restore Options, the product will generate additional steps for this action and the RECPEND step in the Log Restore Member will have duplicate ARYPOBJS DD that may lead to a JCL error.
Local fix
Manually remove the duplicate line.
Problem summary
If you set the Resolve Recover/Rebuild Pending Objects field to Y in the Restore Options, the product will generate additional steps for this action and the RECPEND step in the Log Restore Member will have duplicate ARYPOBJS DD that may lead to a JCL error. You can manually remove the duplicate line as a workaround.
Problem conclusion
Apply the PTF.
Temporary fix
Comments
APAR Information
APAR number
PH51856
Reported component name
DB2 REC EXPERT
Reported component ID
5697H7400
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-01-11
Closed date
2023-02-21
Last modified date
2023-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI90628
Modules/Macros
ARY#PEND ARY$BPND ARY@APRN ARY@DISP ARY@RSTO ARYJOBJ ARYPEND
Fix information
Fixed component name
DB2 REC EXPERT
Fixed component ID
5697H7400
Applicable component levels
R320 PSY UI90628
UP23/02/22 P F302
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.